What the statistic compares
The test first sorts the observations and fits a normal curve using the sample mean and sample standard deviation. It then compares each ordered value with the corresponding fitted cumulative probability. Values in the tails receive substantial weight, which makes the statistic more sensitive to tail departures than some alternatives.
The output is a numerical discrepancy measure, not a probability. A larger A² generally means greater departure in this calculation, but whether that departure is statistically unusual depends on sample size and on the calibration used for estimated parameters. The calculator intentionally reports no p-value or reject/accept flag.
How the fitted-normal statistic is computed
For sorted observations x(1) through x(n), calculate zᵢ = [x(i) − x̄]/s, where s is the sample standard deviation. The reported raw statistic is A² = −n − (1/n)Σ(2i−1){ln Φ(zᵢ) + ln[1−Φ(z(n+1−i))]}, with Φ denoting the standard normal cumulative distribution function.
The calculator uses the sample standard deviation with denominator n−1 and displays A², the sample mean, and the sample standard deviation to eight decimal places. Keep full precision during the calculation; the rounded display is for reading. Extremely remote standardized tails can exceed floating-point probability precision and are rejected rather than silently reported.
Do not treat A² as a standalone verdict
Critical values for a normality test depend on the exact statistic and how the normal parameters were estimated. A raw fitted-normal A² value should not be compared automatically with a generic table or a cutoff taken from a different software package. The calculator supplies neither that calibration nor a p-value; use software with a documented fitted-normal Anderson–Darling procedure when a formal decision is required.
Failure to reject does not prove normality, and rejection does not identify the cause. Small samples may miss subtle departures; large samples may detect minor ones. A probability plot and knowledge of the data-generating process help interpret the statistic.
Check observations and assumptions
The observations should be independent and measured on a scale where differences and a mean are meaningful. Repeated readings from one subject, time-series dependence, clusters, or a mixture of populations can create patterns that a single normal curve cannot represent. The calculator accepts one list; it does not model grouping or dependence.
The data must vary, and the input range is four to 2,000 observations. Before calculation, check transcription, units, missing values, and influential outliers. A strong outlier can dominate a tail-sensitive measure, while rounding can create ties and change the ordered sample. Preserve the original values and document any exclusion rather than cleaning solely to improve the statistic.
Use the result alongside visual and subject checks
Plot a normal probability plot or histogram and compare the observed shape with the assumptions of the analysis that will follow. Look for curvature, skew, heavy tails, multimodality, and isolated points. NIST’s examples pair numerical normality tests with plots because a statistic alone cannot explain which feature of the distribution is unusual.
If normality is important for a later method, consider whether that method is robust, whether a transformation has a defensible meaning, or whether a model suited to the outcome is preferable. Do not select a transformation only because it makes one test statistic smaller. Keep the scientific interpretation and the sampling design central.
Worked examples
A², the sample mean, and sample standard deviation are calculated from the entered observations. Neither example assigns a p-value or decision.
Review a balanced set of eight measurements
Inputs: Observations: 8, 9, 10, 11, 12, 13, 14, 15 data units.
Calculation: The sample mean is x̄ = 11.5 and sample SD s = √(42/7) = 2.44948974. Standardize each sorted value with zᵢ = (x(i)−11.5)/s and apply the fitted-normal sum; A² = 0.13400046.
The calculator reports A² ≈ 0.13400046, mean 11.5, and SD 2.44948974. Without a matching calibration, the statistic alone does not decide normality.
Inspect a sample with a long upper tail
Inputs: Observations: 1, 2, 3, 4, 5, 6, 8, 15 data units.
Calculation: The sample mean is 5.5 and sample SD s = √(137.5/7) = 4.44007722. Standardize the sorted values using these estimates and evaluate the Anderson–Darling tail-weighted sum; A² = 0.46303502.
A² is higher than in the first example, reflecting a larger discrepancy in this calculation. The calculator gives no p-value, so this comparison is descriptive rather than a formal test decision.