Which process question does this chart answer?
A cumulative sum chart keeps evidence from prior observations instead of resetting after every point. Small shifts that persist in one direction can therefore build into a signal even when each individual reading remains near the target.
The two one-sided sums follow possible upward and downward movement separately. A high upper sum indicates accumulating evidence above target; a high lower sum indicates evidence below target. Keeping both is useful when the direction is not known in advance.
Inputs, units, and validation
Enter the current observation, target, process sigma, allowance, decision interval, and previous upper and lower sums. Observations, target, sigma, and allowance must use a consistent measurement scale. Sigma must be positive and the stored cumulative sums nonnegative.
The standardized deviation z=(x−target)/sigma removes the measurement unit. The allowance K defines a small zone of tolerated fluctuation, while the decision interval h determines how much cumulative evidence is required before the chart flags a possible shift.
Formula and worked example
For an upper-sided update, C⁺=max(0,C⁺previous+z−K). For a lower-sided update, C⁻=max(0,C⁻previous−z−K). A sum that drops below zero is reset to zero, so evidence from the opposite direction does not cancel the signal history.
With x=102.5, target 100, sigma 1, K=0.5, h=4, and both previous sums at zero, z=2.5. The upper sum becomes 2.0 and the lower sum remains zero; neither reaches the decision interval.
Read the result in time order
With x=97.2, target 100, sigma 1.2, K=0.5, h=3, previous upper sum 0.2 and lower sum 1.1, z is about −2.3333. The updated upper sum resets to zero and the lower sum rises to about 2.9333.
The calculator returns an update for one observation, not a complete chart history or a recommended value of K and h. Chart design should choose the shift size of interest, false-alarm tolerance, and sampling rhythm before data are interpreted.
Assumptions and limits
A signal means the cumulative statistic crossed the selected decision threshold. It does not locate a change point or identify the cause; check the corresponding time window, measurement method, material, setup, and any recorded process changes.
CUSUM design constants depend on the smallest shift the team wants to detect. A small allowance makes the chart more responsive to small deviations but can also increase nuisance signals if the data are autocorrelated or the reference sigma is inaccurate.
Use the limits consistently
The method assumes a stable target and sigma and observations aligned with the planned chart interval. The single-update calculator does not evaluate run rules, adjust for missing observations, estimate sigma, or compare actual false alarm performance with a design objective.
Keep the prior sums with each observation so the sequence can be reproduced. Use a documented start value and decision interval, then review signals alongside a time plot. the EWMA update calculator provides a related method that weights history exponentially. the CUSUM control chart update calculator
Carry both one-sided sums forward
The first case starts both sums at zero; the second begins with lower-side evidence already accumulated. Update the two directions separately at each observation.
Worked examples
One reading above target
Inputs: x=102.5; target=100; σ=1; K=0.5; h=4; previous C⁺=0; C⁻=0
Calculation: z=(102.5−100)/1=2.5; C⁺=max(0,0+2.5−0.5)=2; C⁻=max(0,0−2.5−0.5)=0
The upper cumulative sum is 2.0 and the lower is 0. Both remain below h=4, so this update alone does not signal.
A downward reading with prior lower evidence
Inputs: x=97.2; target=100; σ=1.2; K=0.5; h=3; previous C⁺=0.2; C⁻=1.1
Calculation: z=(97.2−100)/1.2=−2.3333; C⁺=max(0,0.2+z−0.5)=0; C⁻=max(0,1.1−z−0.5)=2.9333
The lower sum reaches about 2.9333, just below the decision interval of 3.0; this update does not cross the selected threshold.