Separate the two loss mechanisms
When a MOSFET is on, its channel resistance dissipates power. For a constant on-state current I, on-resistance RDS(on), and duty fraction D, the simplified term is Pcond = I²RDS(on)D. It represents conduction during only the fraction of each cycle when the device carries that current. If current varies during the on interval, an RMS current for that interval is a better input than a single peak value.
During a hard transition, drain voltage and drain current overlap for a short time. A triangular overlap approximation gives Psw ≈ ½VI(tr + tf)fs, where V is switched voltage, tr and tf are rise and fall times, and fs is switching frequency. The calculator’s time field is already their sum. These terms capture different mechanisms: lower RDS(on) reduces the first, while shorter transitions or a lower switching rate reduce the second.
Worked examples
Switching overlap exceeds conduction loss
Inputs: I = 5 A, RDS(on) = 20 mΩ, D = 0.40, V = 24 V, tr + tf = 60 ns, fs = 100 kHz.
Calculation: Pcond = 5² × 0.020 × 0.40 = 0.200 W; Psw = ½ × 24 × 5 × 60 × 10⁻⁹ × 100,000 = 0.360 W; total = 0.560 W.
Under these assumptions the transition term is larger. Halving frequency reduces Psw to 0.180 W while leaving Pcond at 0.200 W.
A lower-voltage case is conduction dominated
Inputs: I = 3 A, RDS(on) = 30 mΩ, D = 0.60, V = 12 V, tr + tf = 40 ns, fs = 50 kHz.
Calculation: Pcond = 3² × 0.030 × 0.60 = 0.162 W; Psw = ½ × 12 × 3 × 40 × 10⁻⁹ × 50,000 = 0.036 W; total = 0.198 W.
The on-state term now dominates. The comparison is useful only if the entered current, transition time, and duty describe the same operating condition.
Match each input to the model
Enter on-state current in amperes, resistance in milliohms, and duty as a fraction from zero to one. The tool converts milliohms to ohms by dividing by 1,000. A 40% duty cycle is 0.40, not 40. Switched voltage is entered in volts, the combined rise-plus-fall time in nanoseconds, and frequency in kilohertz. Those units are converted to seconds and hertz inside the calculation.
A dimensional check catches unit mistakes: I²R is watts after converting milliohms to ohms. For switching, VI is power, multiplying by transition time gives energy per cycle, and frequency converts that energy to watts. If a datasheet lists separate rise and fall times, add them once; the field already asks for their sum.
Why a frequency change affects the total
In the first worked example, conduction contributes 0.20 W and transition overlap contributes 0.36 W, for 0.56 W total. If frequency is halved while the other entered quantities stay fixed, the modeled switching term halves to 0.18 W, but conduction remains 0.20 W. The total becomes 0.38 W. This controlled comparison shows why a frequency change does not scale every loss component equally.
The second case is conduction dominated, unlike the first. A larger device may lower on-resistance while increasing gate charge, so compare all changed terms at the same operating point rather than optimizing one number alone.
Check the waveform assumptions
The conduction formula assumes the entered current applies while the switch is on and uses a simple duty multiplier. For a pulsed or ripple-rich load, use the appropriate RMS value over the conduction interval, then account for duty consistently. Do not use a current averaged over the whole cycle as if it were the on-state current unless that conversion is justified by the waveform.
The switching equation treats the drain voltage and current overlap as triangular and uses a single transition interval. Actual waveforms can have nonlinear capacitances, Miller plateaus, diode reverse recovery, ringing, dead time, and load-dependent current. Datasheet switching times are measured at specified gate resistance, voltage, current, and temperature; changing those conditions changes the transition. The estimate is a comparison tool, not a thermal qualification.
What is outside the total
The calculator excludes gate-drive power, output-capacitance energy, body-diode conduction and recovery, snubber loss, and other parasitic effects. It also does not calculate junction temperature or adjust RDS(on) with temperature. A quoted 0.56 W therefore means the sum of these two modeled terms, not every watt lost in a converter or motor driver.
For thermal design, add losses from the rest of the circuit and account for the actual board, package, and cooling path. High-side and low-side switches can have different current waveforms and duty intervals, so estimate them separately. The MOSFET loss calculator totals only the two terms described here.