How to use this calculator
Add same-frequency coherent pressure components while retaining relative phase.
- Enter Individual sound pressure levels (dB re same reference), Matching phases (degrees). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Coherent same frequency sound pressure sum explained
A numerical walkthrough
Individual sound pressure levels (dB re same reference) = 60, 60; Matching phases (degrees) = 0, 0.
- Combined coherent pressure level: 66.02059991 dB
Two in-phase 60 dB pressure components double pressure amplitude. Their combined level rises by 20log10(2)=6.0205999 dB to 66.0205999 dB.
The model behind the numbers
20log10|Σ10^(Li/20)·exp(jφi)|
Convert each level to relative pressure amplitude and resolve it into cosine and sine components. Sum those components before converting their magnitude back to dB. An effectively canceled sum is labeled below numeric resolution rather than assigned a fabricated finite level.
What to enter
l— Individual sound pressure levels (dB re same reference)- Individual sound pressure levels (dB re same reference). Use comma-separated values in the stated order.
p— Matching phases (degrees)- Matching phases (degrees). Use comma-separated values in the stated order.
Interpreting the result
All levels use the same pressure reference at the same observation point. Random uncorrelated sources require energy addition instead.
Frequently asked questions
Can two equal sources cancel?
Yes, ideal opposite phases cancel pressure at that location.
Is this suitable for unrelated noise sources?
No, fixed phase is required.
Why can phase vary with position?
Different propagation paths create different phase delays.
How do I use the Coherent same frequency sound pressure sum calculator?
Enter Individual sound pressure levels (dB re same reference), Matching phases (degrees). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Coherent same frequency sound pressure sum?
Individual sound pressure levels (dB re same reference) = 60, 60; Matching phases (degrees) = 0, 0. Combined coherent pressure level: 66.02059991 dB Two in-phase 60 dB pressure components double pressure amplitude. Their combined level rises by 20log10(2)=6.0205999 dB to 66.0205999 dB.
Read our calculation methodology.