Common mode input error from CMRR calculator

Convert a specified common-mode rejection ratio into an equivalent input-referred error magnitude.

4,000 tools
Common mode input error from CMRR calculator — Common-mode voltage (V), Common-mode rejection ratio (dB) and calculation method
Common mode input error from CMRR calculator: inputs and calculation method.

How to use this calculator

Convert a specified common-mode rejection ratio into an equivalent input-referred error magnitude.

  1. Enter Common-mode voltage (V), Common-mode rejection ratio (dB). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Common mode input error from CMRR explained

Convert a common-mode voltage and the amplifier’s CMRR into the equivalent input-referred error magnitude. CMRR must match the operating frequency and test conditions.

Common mode input error from CMRR0.0001V
Common mode input error from CMRR: 0.00005 V in the worked scenario.

Inputs, symbols, and units

u — Common-mode voltage (V)
Input voltage shared by both amplifier inputs, measured relative to the selected reference.
c — Common-mode rejection ratio (dB)
Ratio of common-mode gain to differential gain expressed as a positive decibel rejection value.

Formula and method

Equivalent input error magnitude=|Vcommon|/10^(CMRR/20).

Symbols use the input definitions below. A frequency-appropriate CMRR and the chosen input reference are required.

A worked scenario

Common-mode voltage (V) = 5; Common-mode rejection ratio (dB) = 100.

  • Common mode input error from CMRR: 0.00005 V

The ratio converts decibels to a linear rejection factor before dividing the common-mode magnitude.

Assumptions and edge cases

A frequency-appropriate CMRR and the chosen input reference are required. It does not include resistor-network mismatch.

Frequently asked questions

Is this output error?

No, multiply by the applicable closed-loop signal gain if appropriate.

Can CMRR change with frequency?

Yes, use the value for the operating conditions.

Does polarity follow this magnitude?

No, the error sign is not predicted.

How do I use the Common mode input error from CMRR calculator?

Enter Common-mode voltage (V), Common-mode rejection ratio (dB). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Common mode input error from CMRR?

Common-mode voltage (V) = 5; Common-mode rejection ratio (dB) = 100. Common mode input error from CMRR: 0.00005 V The ratio converts decibels to a linear rejection factor before dividing the common-mode magnitude.