How to use this calculator
Transform a short real or complex sample block into its full two-sided discrete frequency spectrum.
- Enter Real sample components, Imaginary components, same length, Sampling rate (Hz). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Discrete Fourier transform spectrum explained
How the calculation works
X[k]=Σx[n]e^(−j2πkn/N), unnormalized forward DFT
For each bin, rotate every complex sample by the negative bin phase and sum its real and imaginary contributions. Frequencies above the positive Nyquist index are labeled as wrapped negative frequencies. No magnitude, window, or sample-count normalization is hidden.
Set up the calculation
r— Real sample components- Real sample components. Use comma-separated values in the stated order.
i— Imaginary components, same length- Imaginary components, same length. Use comma-separated values in the stated order.
fs— Sampling rate (Hz)- Sampling rate (Hz).
Limits of this model
Up to 256 samples with no automatic window. Forward transform is unnormalized, and amplitudes are not doubled into a one-sided spectrum.
Check this example
Real sample components = 1, 0, -1, 0; Imaginary components, same length = 0, 0, 0, 0; Sampling rate (Hz) = 8.
- DC magnitude: 0
- Bins: frequency, real, imaginary: 0 Hz: 0, 0; 2 Hz: 2, 1.224647e-16; 4 Hz: 0, -2.449294e-16; -2 Hz: 2, 3.673940e-16
For samples [1,0,−1,0] with zero imaginary part, DC is zero. The full unnormalized transform is [0,2,0,2], with the last bin representing the negative-frequency partner.
Source
SciPy FFT tutorial, Discrete Fourier Transform section. Describes the length-N transform and normalization conventions; this calculator reports the unnormalized forward DFT.
Interpreting the result
The DC bin is the magnitude of the sample sum, so it is zero for the default sequence whose positive and negative samples cancel. Other bins describe discrete frequency components; magnitude alone omits phase, and this forward transform is unnormalized.
Frequently asked questions
Do negative frequencies appear?
Bins above Nyquist represent wrapped negative frequencies.
Is the transform normalized by N?
No, divide magnitudes by N when that normalization is intended.
Are samples windowed automatically?
No.
How do I use the Discrete Fourier transform spectrum calculator?
Enter Real sample components, Imaginary components, same length, Sampling rate (Hz). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Discrete Fourier transform spectrum?
Real sample components = 1, 0, -1, 0; Imaginary components, same length = 0, 0, 0, 0; Sampling rate (Hz) = 8. DC magnitude: 0 Bins: frequency, real, imaginary: 0 Hz: 0, 0; 2 Hz: 2, 1.224647e-16; 4 Hz: 0, -2.449294e-16; -2 Hz: 2, 3.673940e-16 For samples [1,0,−1,0] with zero imaginary part, DC is zero. The full unnormalized transform is [0,2,0,2], with the last bin representing the negative-frequency partner.
Read our calculation methodology.