How to use this calculator
Estimate an unknown band size from a local semilog fit to supplied ladder measurements.
- Enter Marker migration distances (mm), Matching marker sizes (base pairs), Unknown band migration (mm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
DNA gel migration semilog calibration explained
Use Marker migration distances (mm) with Matching marker sizes (base pairs) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
A numerical walkthrough
Marker migration distances (mm) = 10, 20, 30; Matching marker sizes (base pairs) = 10000, 1000, 100; Unknown band migration (mm) = 25.
- Estimated linear DNA size: 316.227766 bp
- Log-size fit R²: 1
Each extra 10 mm in the example corresponds to a tenfold smaller fragment. Halfway between 1,000 and 100 bp on the logarithmic scale gives sqrt(1000×100)=316.227766 bp.
The model behind the numbers
Fit log10(bp)=intercept+slope·distance
Fit log10 marker size against measured migration distance, then exponentiate the predicted log size at the unknown band. This is a local calibration with an explicit in-range query check. The fit should not be interpreted as a universal gel-mobility law.
What to enter
d— Marker migration distances (mm)- Marker migration distances (mm). Use comma-separated values in the stated order.
b— Matching marker sizes (base pairs)- Matching marker sizes (base pairs). Use comma-separated values in the stated order.
x— Unknown band migration (mm)- Unknown band migration (mm).
Interpreting the result
Unknown distance must lie within the calibration range. Gel conditions, DNA conformation, broad-range curvature, and unresolved bands can invalidate a single straight-line fit.
Frequently asked questions
Can supercoiled plasmid bands use a linear-fragment ladder directly?
Their migration can differ, so this calibration may not apply.
Why logarithmic fragment size?
A local migration-versus-log-size relationship is often the intended empirical calibration.
Is extrapolation allowed?
No, this tool limits queries to the supplied marker range.
How do I use the DNA gel migration semilog calibration calculator?
Enter Marker migration distances (mm), Matching marker sizes (base pairs), Unknown band migration (mm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of DNA gel migration semilog calibration?
Marker migration distances (mm) = 10, 20, 30; Matching marker sizes (base pairs) = 10000, 1000, 100; Unknown band migration (mm) = 25. Estimated linear DNA size: 316.227766 bp Log-size fit R²: 1 Each extra 10 mm in the example corresponds to a tenfold smaller fragment. Halfway between 1,000 and 100 bp on the logarithmic scale gives sqrt(1000×100)=316.227766 bp.
Read our calculation methodology.