CalcWorldHub
Free online calculator · no signup

EDF periodic task utilization test calculator

Apply the ideal earliest-deadline-first utilization test to independent periodic tasks with deadlines equal to periods.

4,000 tools
EDF periodic task utilization test calculator — Worst-case execution times, Task periods and relative deadlines and calculation method
EDF periodic task utilization test calculator: inputs and calculation method.

How to use this calculator

Apply the ideal earliest-deadline-first utilization test to independent periodic tasks with deadlines equal to periods.

  1. Enter Worst-case execution times, Task periods and relative deadlines. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

EDF periodic task utilization test explained

For independent periodic jobs on one preemptive processor, implicit deadlines equal to each task period have a simple EDF feasibility test: total execution-time utilization must not exceed one. This check does not cover constrained deadlines or scheduling overhead.

Inputs, symbols, and units

c — Worst-case execution times
Worst-case execution times. Enter comma-separated execution times Cᵢ in the same order as the periods.
t — Task periods and relative deadlines
Task periods and relative deadlines. Enter comma-separated execution times Cᵢ in the same order as the periods.

Formula and method

U = Σ(Cᵢ/Tᵢ). For independent periodic tasks with relative deadline Dᵢ=Tᵢ on one ideal preemptive processor, the EDF test passes when U ≤ 1.

Single preemptive processor, zero scheduling overhead, no blocking, and each relative deadline equals its period; constrained deadlines need another schedulability test.

A worked scenario

Worst-case execution times = 1, 2, 1; Task periods and relative deadlines = 4, 5, 10.

  • Total task utilization: 0.75
  • Ideal EDF test: Pass under stated assumptions

For (Cᵢ,Tᵢ)=(1,4),(2,5),(1,10), U=1/4+2/5+1/10=0.75, so the ideal implicit-deadline EDF test passes.

Assumptions and edge cases

Single preemptive processor, zero scheduling overhead, no blocking, and deadline=period for every task.

Frequently asked questions

Is utilization ≤1 sufficient here?

Yes under the stated ideal assumptions.

Can deadlines be shorter than periods?

Not with this simple test.

Does it model multicore scheduling?

No.

How do I use the EDF periodic task utilization test calculator?

Enter Worst-case execution times, Task periods and relative deadlines. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of EDF periodic task utilization test?

Worst-case execution times = 1, 2, 1; Task periods and relative deadlines = 4, 5, 10. Total task utilization: 0.75 Ideal EDF test: Pass under stated assumptions For (Cᵢ,Tᵢ)=(1,4),(2,5),(1,10), U=1/4+2/5+1/10=0.75, so the ideal implicit-deadline EDF test passes.