How to use this calculator
Estimate stock-solution injection flow and run time for a target nutrient concentration.
- Enter Irrigation water flow (L/min), Target final nutrient concentration (mg/L), Incoming-water nutrient concentration (mg/L), Prepared stock concentration (mg/L), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Fertigation dosing connects a prepared nutrient stock with the irrigation stream. This calculator includes nutrient already present in incoming water and uses a direct mixed-flow mass balance to estimate the stock flow needed to reach the selected final concentration.
Inputs and units
waterFlow— Irrigation water flow (L/min)- Use the flow entering the mixing point before fertilizer stock is added.
targetConcentration— Target final nutrient concentration (mg/L)- Enter the desired concentration in the combined irrigation stream.
backgroundConcentration— Incoming-water nutrient concentration (mg/L)- Subtract nutrient already present in source water; use 0 if not measured or not being accounted for.
stockConcentration— Prepared stock concentration (mg/L)- Use concentration of the same nutrient in the diluted stock tank solution.
stockVolume— Usable stock volume (L)- Enter the stock volume available for this irrigation event.
Formula
Let Qw be irrigation flow, Ct the target final concentration, Cb the background concentration, and Cs the stock concentration. From Qw·Cb + Qi·Cs = (Qw + Qi)·Ct, injection flow Qi = Qw·(Ct − Cb)/(Cs − Ct). Injection time = usable stock volume/Qi when Qi > 0.
Method
All concentrations use the same nutrient basis and mg/L units; both flows use L/min. The equation balances nutrient mass entering with nutrient mass in the final mixed stream. If the target already equals the background level, the required added stock flow is zero.
Worked example
With 1,000 L/min of irrigation water at 10 mg/L, a 150 mg/L final target, and stock at 300,000 mg/L, Qi = 1,000 × (150−10)/(300,000−150) ≈ 0.4669 L/min. A 60 L tank would last about 128.51 minutes at that rate.
Assumptions and limits
This is a concentration and injector-flow estimate, not a crop nutrient recommendation. Use the nutrient concentration of the prepared stock solution, not just the fertilizer product grade; convert mass percent using the product label and solution density when needed. Check injector capacity, compatibility, backflow protection, calibration, field recommendations, and local environmental requirements before application.
Frequently asked questions
Should the target concentration include nutrients already in the water?
The calculator lets you enter a background concentration and subtracts it from the target. Use a representative water analysis when that difference matters.
Can I enter fertilizer grade such as 32-0-0 as the stock concentration?
Not directly. The field expects mg/L of the nutrient in the prepared stock solution. Converting a product grade requires its nutrient fraction and solution density or a measured stock concentration.
What if the target is the same as the incoming concentration?
The result is zero stock flow and reports that no injection is needed for the selected target.
How do I use the Fertigation Injection Rate Calculator?
Enter Irrigation water flow (L/min), Target final nutrient concentration (mg/L), Incoming-water nutrient concentration (mg/L), Prepared stock concentration (mg/L), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Fertigation Injection Rate?
With 1,000 L/min of irrigation water at 10 mg/L, a 150 mg/L final target, and stock at 300,000 mg/L, Qi = 1,000 × (150−10)/(300,000−150) ≈ 0.4669 L/min. A 60 L tank would last about 128.51 minutes at that rate.
Reference: University of Florida IFAS Extension guide to fertigation injection rate and concentration mixing. See our calculation methodology.