CalcWorldHub
Free online calculator · no signup

First order ARX plant identification calculator

Estimate a simple sampled plant from an actual paired command and output record.

4,000 tools
First order ARX plant identification calculator — Input samples, Output samples and calculation method
First order ARX plant identification calculator: inputs and calculation method.

How to use this calculator

Estimate a simple sampled plant from an actual paired command and output record.

  1. Enter Input samples, Output samples. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

First order ARX plant identification explained

The default time series includes input changes and output decay; this fit estimates a one-step ARX model from those aligned samples and does not establish that the model predicts outside the observed range.

Estimated autoregressive coefficient0.5934ratio
Estimated autoregressive coefficient: 0.593352 ratio in the worked scenario.

Inputs, symbols, and units

u — Input samples
Uniformly sampled actuator history, same length as output. Use comma-separated values in the stated order.
y — Output samples
Observed outputs; model uses y[k]=a y[k−1]+b u[k−1]+c. Use comma-separated values in the stated order.

Formula and method

Fit yₖ=a yₖ₋₁+b uₖ₋₁+c by ordinary least squares: θ=(XᵀX)⁻¹Xᵀy.

The one-sample input delay is explicit. Include informative input changes; a constant input or collinear regressors cannot identify all three parameters.

A worked scenario

Input samples = [0, 1, 1, 0, 0, 1, 1]; Output samples = [0, 0, 0.8, 1.3, 0.75, 0.5, 1.1].

  • Estimated autoregressive coefficient: 0.593352 ratio
  • Estimated delayed input coefficient: 0.798338 output/input
  • Estimated offset: 0.011209 output
  • Residual RMS: 0.024088 output

The default seven-sample record includes both actuator changes and decay intervals; fit its lag coefficient, input coefficient and offset.

Assumptions and edge cases

No instrumental variables, closed-loop bias correction or errors-in-variables model. Poorly conditioned histories are rejected.

Reading the outputs

Residual RMS uses all fitted one-step errors with divisor n−1; it is not an unbiased measurement-noise estimate.

Frequently asked questions

Why use previous input?

This ARX model assumes one sample of causal input delay.

Can these coefficients define a simulator?

Yes, but validate on a separate record before trusting long predictions.

Why does constant input fail?

The input column becomes collinear with the offset column.

How do I use the First order ARX plant identification calculator?

Enter Input samples, Output samples. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of First order ARX plant identification?

Input samples = [0, 1, 1, 0, 0, 1, 1]; Output samples = [0, 0, 0.8, 1.3, 0.75, 0.5, 1.1]. Estimated autoregressive coefficient: 0.593352 ratio Estimated delayed input coefficient: 0.798338 output/input Estimated offset: 0.011209 output Residual RMS: 0.024088 output The default seven-sample record includes both actuator changes and decay intervals; fit its lag coefficient, input coefficient and offset.