How to use this calculator
Predict how an open-loop buck converter rises above Vin times duty at a light load when the inductor current becomes discontinuous.
- Enter Input voltage (V), Applied duty cycle, Inductor value (H), Switching frequency (Hz), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Fixed-duty buck CCM and DCM operating point explained
For an ideal fixed-duty buck with diode emulation, compare K=2Lf/R with 1−D to choose CCM or DCM; at light load the DCM conversion ratio depends on L, f, and R.
A numerical walkthrough
Input voltage (V) = 24; Applied duty cycle = 0.3; Inductor value (H) = 0.0001; Switching frequency (Hz) = 100000; Resistive output load (ohm) = 100.
- Steady output voltage: 11.581166 V
- CCM flag: 0 1 CCM; 0 DCM
- DC load current: 0.115812 A
At 24 V, duty 0.3, 100 microhenries and 100 kHz, a 100 ohm load is light enough to leave the simple CCM voltage law.
The model behind the numbers
K=2Lf/R; M=D in CCM when K≥1−D; otherwise K M²=D²(1−M), with M=V_OUT/V_IN.
A diode-emulation or asynchronous buck cannot sustain negative inductor current. Charge balance in the triangular DCM waveform makes gain load-dependent.
What to enter
Vin— Input voltage (V)- Ideal positive DC source.
D— Applied duty cycle- Fixed on-time fraction, independent of any regulation loop.
L— Inductor value (H)- Positive linear inductance.
f— Switching frequency (Hz)- Fixed switching cycles per second.
R— Resistive output load (ohm)- Load resistance for the steady operating point.
Interpreting the result
Ideal fixed-duty buck, small output ripple and resistive load. Not valid for forced-continuous synchronous current, diode losses or closed-loop duty adjustment.
Reading the outputs
The numeric flag reports the mode selected by the boundary criterion. At the exact boundary both equations meet continuously.
Frequently asked questions
Why is light-load output above D times Vin?
Current reaches zero before the next cycle, changing charge balance and the conversion ratio.
Does a regulated buck show this full voltage rise?
Its control loop normally reduces duty to maintain the target voltage.
Can this model a synchronous converter that allows reverse current?
No; forced continuous conduction can retain the CCM law at light load.
How do I use the Fixed-duty buck CCM and DCM operating point calculator?
Enter Input voltage (V), Applied duty cycle, Inductor value (H), Switching frequency (Hz), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Fixed-duty buck CCM and DCM operating point?
Input voltage (V) = 24; Applied duty cycle = 0.3; Inductor value (H) = 0.0001; Switching frequency (Hz) = 100000; Resistive output load (ohm) = 100. Steady output voltage: 11.581166 V CCM flag: 0 1 CCM; 0 DCM DC load current: 0.115812 A At 24 V, duty 0.3, 100 microhenries and 100 kHz, a 100 ohm load is light enough to leave the simple CCM voltage law.
Background or definition reference: Texas Instruments SLVA057: buck continuous and discontinuous operation.
Read our calculation methodology.