How to use this calculator
Estimate minimum nominal flow per injector for a target engine power, using BSFC, injector count, and a maximum duty fraction.
- Enter Target crankshaft power (hp), BSFC (lb/hp·h), Number of injectors, Target maximum duty cycle (%). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How Fuel injector flow sizing calculator works
Estimate minimum nominal flow per injector for a target engine power, using BSFC, injector count, and a maximum duty fraction.
Inputs and units
- Target crankshaft power (hp): Target crankshaft power is the engine power goal in horsepower.
- BSFC (lb/hp·h): BSFC is brake-specific fuel consumption in lb/(hp·h).
- Number of injectors: Number of injectors is the count sharing the total required fuel flow.
- Target maximum duty cycle (%): Target maximum duty cycle is a percentage from 0 to 100; enter a positive value below 100 for a design margin.
Formula and method
Flow per injector=(power·BSFC)/(injector count·duty fraction), where duty fraction=duty percent/100.
Worked example
For 320 hp, BSFC 0.52 lb/(hp·h), four injectors, and 80% duty, flow=320·0.52/(4·0.8)=52 lb/h per injector.
Interpreting the result
The result is a nominal flow rating per injector at the assumed operating pressure and fuel. A lower duty target increases the required rated flow.
Assumptions and limits
This is a sizing estimate, not an engine guarantee. Actual flow depends on fuel, injector differential pressure, calibration, pump capacity, and whether the stated power is measured at the crankshaft or wheels.
Sources and method
- Injector size depends on horsepower, BSFC, injector count, and duty cycle; pressure and operating assumptions also matter. Holley fuel-injector technical guide
Frequently asked questions
Why divide by duty cycle?
The injector is allowed to deliver only that fraction of its nominal full-time flow.
Does this calculator size the fuel pump too?
No. It estimates injector flow only; pump capacity and pressure losses need separate checks.
How do I use the Fuel injector flow sizing calculator?
Enter Target crankshaft power (hp), BSFC (lb/hp·h), Number of injectors, Target maximum duty cycle (%). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Fuel injector flow sizing?
For 320 hp, BSFC 0.52 lb/(hp·h), four injectors, and 80% duty, flow=320·0.52/(4·0.8)=52 lb/h per injector.
What does the Fuel injector flow sizing calculator calculate?
Estimate minimum nominal flow per injector for a target engine power, using BSFC, injector count, and a maximum duty fraction.