How to use this calculator
Estimate a first-pass reservoir capacitor from DC load current, mains frequency, and allowed peak-to-peak ripple after full-wave rectification.
- Enter Average DC load current (A), AC line frequency (Hz), Allowed output ripple (V peak-to-peak). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
A reservoir capacitor supplies a load between rectified voltage peaks. With full-wave rectification, the capacitor is refreshed twice per AC line cycle. This first-order estimate uses the load current and the allowed discharge ripple to calculate a minimum capacitance.
Inputs and units
loadCurrentA— Average DC load current (A)- Approximate steady current drawn from the smoothed DC output.
lineFrequencyHz— AC line frequency (Hz)- Input mains frequency; full-wave rectification produces two ripple periods per line cycle.
rippleVpp— Allowed output ripple (V peak-to-peak)- Maximum approximate capacitor discharge ripple between rectified peaks.
Formula
Ripple frequency fr = 2·fline. Approximate capacitance C(F) = Iload ÷ (fr·ΔVpp). In microfarads, C(µF) = 1,000,000·Iload ÷ (2·fline·ΔVpp).
Method
The relation follows from I = C·ΔV/Δt and assumes a roughly constant load current while the capacitor discharges between full-wave peaks. It estimates the reservoir capacitance only.
Worked example
At 0.5 A, 60 Hz mains, and 1.0 V peak-to-peak allowed ripple, fr = 120 Hz and C ≈ 0.5/(120×1.0) = 0.004167 F, or about 4,167 µF.
Assumptions and limits
This first-order estimate assumes approximately constant load current and small ripple over each interval between charging peaks. It does not model transformer regulation, diode conduction angle, capacitor ESR, load transients, temperature, tolerance, voltage rating, or surge current. Choose a rated capacitor and verify the full supply design.
Frequently asked questions
Why is ripple frequency twice the mains frequency?
A full-wave bridge produces a charging peak on both half-cycles of the AC input.
Is this the exact capacitor value needed in a power supply?
No. It is a first-pass discharge estimate. Real supply design also checks transformer regulation, diode drops, ESR, ripple-current rating, inrush, load variation, and voltage rating.
What changes with a half-wave rectifier?
The capacitor is replenished once per line cycle, so the ripple interval is longer; this page specifically assumes full-wave rectification.
How do I use the Full-Wave Rectifier Ripple Capacitor Calculator?
Enter Average DC load current (A), AC line frequency (Hz), Allowed output ripple (V peak-to-peak). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Full-Wave Rectifier Ripple Capacitor?
At 0.5 A, 60 Hz mains, and 1.0 V peak-to-peak allowed ripple, fr = 120 Hz and C ≈ 0.5/(120×1.0) = 0.004167 F, or about 4,167 µF.
Read our calculation methodology.