How to use this calculator
Estimate transmitted photon intensity and shielding thickness for a narrow-beam attenuation model.
- Enter Incident intensity (same units as output), Linear attenuation coefficient (cm⁻¹), Material thickness (cm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The narrow-beam exponential model estimates how an uncollided monoenergetic photon beam is attenuated by a uniform material. This tool reports transmitted intensity, transmission, and half- and tenth-value thicknesses from a linear attenuation coefficient.
Inputs and units
incidentIntensity— Incident intensity (same units as output)- Unattenuated intensity entering the material.
mu— Linear attenuation coefficient (cm⁻¹)- Linear photon attenuation coefficient for the selected material and energy.
thickness— Material thickness (cm)- Uniform shielding thickness along the beam path.
Formula
I = I₀ exp(−μx); HVL = ln(2)/μ; TVL = ln(10)/μ.
Method
Enter the incident intensity, the material's linear attenuation coefficient in cm⁻¹, and thickness in cm. Intensity units are preserved. HVL and TVL use the same thickness unit as the entered coefficient.
Worked example
For an incident intensity of 1,000, μ = 0.12 cm⁻¹, and 3 cm of material, the model gives 697.68 transmitted intensity units, 69.77% transmission, an HVL of 5.78 cm, and a TVL of 19.19 cm.
Assumptions and limits
This ideal narrow-beam relation excludes scattered photons reaching the detector, beam hardening, broad-spectrum effects, buildup, and heterogeneous shielding. Use an energy- and material-appropriate coefficient; real shielding design may require transport calculations.
Frequently asked questions
What does the narrow-beam model calculate?
It estimates the uncollided beam intensity remaining after exponential attenuation in a uniform material.
Does this include scattered radiation?
No. Broad-beam buildup and photons scattered into the detector are outside this simple model.
How do I choose μ?
Use a coefficient for the material and photon energy; mass attenuation tables must be multiplied by material density to obtain a linear coefficient.
How do I use the Gamma and X-Ray Narrow-Beam Attenuation Calculator?
Enter Incident intensity (same units as output), Linear attenuation coefficient (cm⁻¹), Material thickness (cm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Gamma and X-Ray Narrow-Beam Attenuation?
For an incident intensity of 1,000, μ = 0.12 cm⁻¹, and 3 cm of material, the model gives 697.68 transmitted intensity units, 69.77% transmission, an HVL of 5.78 cm, and a TVL of 19.19 cm.
Reference: U.S. NRC Advanced Health Physics narrow-beam photon attenuation equation. See our calculation methodology.