How to use this calculator
Estimate apparent temperature from Fahrenheit air temperature and relative humidity using the National Weather Service method.
- Enter Air temperature (°F), Relative humidity (%). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The heat index combines air temperature and humidity into an apparent-temperature estimate for shaded conditions. This page applies the National Weather Service's simple low-range calculation and Rothfusz regression adjustments, while stating the conditions where the regression should not be trusted.
Inputs and units
temperatureF— Air temperature (°F)- Use a shaded air-temperature reading in degrees Fahrenheit.
relativeHumidity— Relative humidity (%)- Enter relative humidity as a percentage from 0 to 100.
Formula
First compute S = 0.5 × [T + 61 + 1.2(T − 68) + 0.094RH], then Hs = (S + T) ÷ 2. If Hs < 80°F, use Hs. Otherwise use Rothfusz: HI = −42.379 + 2.04901523T + 10.14333127RH − 0.22475541TRH − 0.00683783T² − 0.05481717RH² + 0.00122874T²RH + 0.00085282TRH² − 0.00000199T²RH², with NWS low- or high-humidity adjustment when applicable.
Method
Enter air temperature in °F and relative humidity from 0 to 100%. The calculator first evaluates the simple estimate; if its average with air temperature is below 80°F, that value is used. Otherwise it uses the Rothfusz regression and NWS humidity adjustments.
Worked example
At 95°F and 55% relative humidity, the Rothfusz regression gives an apparent temperature of about 108.95°F before display rounding.
Assumptions and limits
The regression is an approximation for shady conditions and is not valid for extreme temperature-humidity combinations outside its development range. Direct sun can raise apparent heat exposure; this is not a personal medical risk assessment or a substitute for local heat guidance.
Frequently asked questions
Does heat index include direct sunlight?
No. The standard heat-index value is for shade; direct sun can increase heat exposure.
When does the Rothfusz regression apply?
The NWS uses a simpler estimate below about 80°F apparent temperature and cautions against regression results outside the studied range.
Is heat index the same as wet-bulb globe temperature?
No. WBGT includes additional environmental factors and is used for different heat-stress assessments.
How do I use the Heat index calculator?
Enter Air temperature (°F), Relative humidity (%). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Heat index?
At 95°F and 55% relative humidity, the Rothfusz regression gives an apparent temperature of about 108.95°F before display rounding.
Reference: National Weather Service calculation guidance. See our calculation methodology.