Impedance reflection and standing wave ratio calculator

Evaluate reflection magnitude, standing-wave ratio, and mismatch loss for a passive complex load.

4,000 tools
Impedance reflection and standing wave ratio calculator — Load resistance (Ω), Load reactance (Ω), Real line impedance (Ω) and calculation method
Impedance reflection and standing wave ratio calculator: inputs and calculation method.

How to use this calculator

Evaluate reflection magnitude, standing-wave ratio, and mismatch loss for a passive complex load.

  1. Enter Load resistance (Ω), Load reactance (Ω), Real line impedance (Ω). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Impedance reflection and standing wave ratio explained

A load’s complex impedance determines its voltage-wave reflection relative to a real characteristic impedance. This calculator derives the reflection coefficient magnitude and phase, then converts the magnitude to standing-wave ratio; zero reflection occurs only when load and line impedances match.

Standing wave ratio1.7676
Standing wave ratio: 1.767592 in the worked scenario.

Inputs, symbols, and units

r — Load resistance (Ω)
Load resistance (Ω).
x — Load reactance (Ω)
Load reactance (Ω).
z — Real line impedance (Ω)
Real line impedance (Ω).

Formula and method

|Γ|=|Zload−Z0|/|Zload+Z0|; SWR=(1+|Γ|)/(1−|Γ|).

Symbols use the input definitions below. Reference line impedance is positive and real; losses along the line are excluded..

A worked scenario

Load resistance (Ω) = 75; Load reactance (Ω) = 25; Real line impedance (Ω) = 50.

  • Standing wave ratio: 1.767592
  • Reflection magnitude: 0.27735
  • Mismatch loss: 0.347621 dB

This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.

Assumptions and edge cases

Reference line impedance is positive and real; losses along the line are excluded.

Frequently asked questions

Can SWR be infinite?

Yes, for full reflection.

Does low SWR prove high efficiency?

No, dissipative loss can hide mismatch.

Is reactance sign supported?

Yes.

How do I use the Impedance reflection and standing wave ratio calculator?

Enter Load resistance (Ω), Load reactance (Ω), Real line impedance (Ω). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Impedance reflection and standing wave ratio?

Load resistance (Ω) = 75; Load reactance (Ω) = 25; Real line impedance (Ω) = 50. Standing wave ratio: 1.767592 Reflection magnitude: 0.27735 Mismatch loss: 0.347621 dB This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.