CalcWorldHub
Free online calculator · no signup

Multiplicity of Infection (MOI) Calculator

Calculate the infectious units and stock volume needed for a target multiplicity of infection.

4,000 tools
Multiplicity of Infection (MOI) Calculator — Target cell count, Target MOI (infectious units per cell), Functional stock titer (units/mL) and calculation method
Multiplicity of Infection (MOI) Calculator: inputs and calculation method.

How to use this calculator

Calculate the infectious units and stock volume needed for a target multiplicity of infection.

  1. Enter Target cell count, Target MOI (infectious units per cell), Functional stock titer (units/mL). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Biology calculation

How this calculation works

Multiplicity of infection is the ratio of infectious units applied to target cells. A Poisson model also estimates the fraction of cells receiving at least one infectious unit when exposure events are independent and equally likely.

Inputs and units

targetCells — Target cell count
Number of cells present when the inoculum is applied.
targetMoi — Target MOI (infectious units per cell)
Desired mean infectious units per target cell.
stockTiterPerMl — Functional stock titer (units/mL)
Matching infectious or transducing units per millilitre.

Formula

Displayed formula

MOI = infectious units / cells; stock volume = MOI × cells / titer; P(at least one) = 1 − e⁻ᴹᴼᴵ.

Method

Enter the number of target cells, target MOI, and functional stock titer in infectious units per millilitre. The calculator estimates the required inoculum volume and a Poisson at-least-one exposure fraction.

Worked example

For 1,000,000 cells at MOI 0.5 with a 1×10⁸ infectious-units/mL stock, add 5 µL; the idealized Poisson fraction with at least one unit is 39.35%.

Assumptions and limits

Use a functional infectious or transducing titer such as PFU/mL or TU/mL that matches the experiment; physical genome copies are not interchangeable with infectious units. The Poisson fraction is an idealized exposure model, not a guarantee of infection or expression.

Frequently asked questions

What units should I use for titer?

Use a functional assay-matched titer such as PFU/mL or TU/mL; genome copies per millilitre may include noninfectious particles.

What does MOI 0.5 mean?

It means an average of 0.5 infectious units applied per target cell, not that exactly half the cells will be infected.

Why is the Poisson fraction below 50% at MOI 0.5?

Under the idealized model, the probability of at least one unit is 1 − e⁻⁰·⁵, about 39.35%.

How do I use the Multiplicity of Infection (MOI) Calculator?

Enter Target cell count, Target MOI (infectious units per cell), Functional stock titer (units/mL). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Multiplicity of Infection (MOI)?

For 1,000,000 cells at MOI 0.5 with a 1×10⁸ infectious-units/mL stock, add 5 µL; the idealized Poisson fraction with at least one unit is 39.35%.