Orifice flow rate calculator
Estimate incompressible flow through an orifice from discharge coefficient and pressure difference. Enter your values below to see the result and method.
inputs.
Related calculators
These tools cover nearby questions while keeping this page focused on its own calculation.
How to use this calculator
Estimate incompressible flow through an orifice from discharge coefficient and pressure difference.
- Enter Discharge coefficient Cᵈ, Orifice area (mm²), Pressure difference (kPa), Fluid density (kg/m³). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Define the component and operating point
This incompressible-orifice estimate uses pressure drop, density, open area, and discharge coefficient. Compressibility, cavitation, viscosity, and installation geometry can change actual flow. Estimate incompressible flow through an orifice from discharge coefficient and pressure difference.
Inputs and units
Use the units printed beside each field. These values are Discharge coefficient Cᵈ, Orifice area (mm²), Pressure difference (kPa), Fluid density (kg/m³).
- Discharge coefficient Cᵈ: Discharge coefficient Cᵈ as defined for the physical or engineering situation.
- Orifice area (mm²): Orifice area as defined for the physical or engineering situation.
- Pressure difference (kPa): Pressure difference as defined for the physical or engineering situation.
- Fluid density (kg/m³): Fluid density as defined for the physical or engineering situation.
Design equation and example
Q = CᵈA√(2Δp/ρ), using SI area and pressure.
Cᵈ=0.62, area 100 mm², Δp=20 kPa, and density 1000 kg/m³ give about 0.391 L/s.
Intermediate values are kept unrounded; the displayed result is rounded for readability.
Applying the result in a system
Treat this as a calculation for the stated component and operating point. Real installations can add losses, tolerances, boundary conditions, or code requirements beyond this model.
Assumptions and limitations
Ideal incompressible estimate; geometry, cavitation, viscosity, and downstream pressure can change actual flow.
Frequently asked questions
Which measurements belong in the orifice flow rate?
Enter Discharge coefficient Cᵈ, Orifice area (mm²), Pressure difference (kPa), Fluid density (kg/m³). Verify that the values use the same operating condition and unit system.
What can make a real installation differ from this orifice flow rate estimate?
Ideal incompressible estimate; geometry, cavitation, viscosity, and downstream pressure can change actual flow.
How do I use the Orifice flow rate calculator?
Enter Discharge coefficient Cᵈ, Orifice area (mm²), Pressure difference (kPa), Fluid density (kg/m³). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Orifice flow rate?
Q = CᵈA√(2Δp/ρ), using SI area and pressure. Cᵈ=0.62, area 100 mm², Δp=20 kPa, and density 1000 kg/m³ give about 0.391 L/s. Intermediate values are kept unrounded; the displayed result is rounded for readability.
What does the Orifice flow rate calculator calculate?
Estimate incompressible flow through an orifice from discharge coefficient and pressure difference.
Read the calculation methodology and privacy policy.