CalcWorldHub
Free online calculator · no signup

Pump input power calculator

Estimate pump input power needed to move a fluid through a specified head at a stated efficiency. Enter your values below to see the result and method.

A better way to figure it out
Clear
inputs.
∑
Clear result · useful details
Free calculatorNo signup ✓

Related calculators

These tools cover nearby questions while keeping this page focused on its own calculation.

Browse engineering calculators →

Pump input power calculator — Flow rate (L/s), Total head (m), Pump efficiency (%) and calculation method
Pump input power calculator: inputs and calculation method.

How to use this calculator

Estimate pump input power needed to move a fluid through a specified head at a stated efficiency.

  1. Enter Flow rate (L/s), Total head (m), Pump efficiency (%), Fluid density (kg/m³). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Free calculator guide

Define the component and operating point

Input power is hydraulic power divided by pump efficiency. The handler reports watts; 7,845 W is about 7.845 kW for the example inputs. Estimate pump input power needed to move a fluid through a specified head at a stated efficiency.

∑
Original CalcWorldHub illustration for this calculation.

Inputs and units

Use the units printed beside each field. These values are Flow rate (L/s), Total head (m), Pump efficiency (%), Fluid density (kg/m³).

Design equation and example

Pᵢ = ρgQH ÷ η, with Q converted to m³/s and η to a fraction.

20 L/s at 30 m head, 75% efficiency, and water density requires about 7.845 kW.

Intermediate values are kept unrounded; the displayed result is rounded for readability.

Applying the result in a system

Input power is hydraulic power divided by pump efficiency. The handler reports watts; 7,845 W is about 7.845 kW for the example inputs.

Assumptions and limitations

Excludes motor and drive losses unless included in the entered efficiency; actual operating point depends on the pump and system curve.

Frequently asked questions

Which measurements belong in the pump input power?

Enter Flow rate (L/s), Total head (m), Pump efficiency (%), Fluid density (kg/m³). Verify that the values use the same operating condition and unit system.

What can make a real installation differ from this pump input power estimate?

Excludes motor and drive losses unless included in the entered efficiency; actual operating point depends on the pump and system curve.

How do I use the Pump input power calculator?

Enter Flow rate (L/s), Total head (m), Pump efficiency (%), Fluid density (kg/m³). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Pump input power?

Pᵢ = ρgQH ÷ η, with Q converted to m³/s and η to a fraction. 20 L/s at 30 m head, 75% efficiency, and water density requires about 7.845 kW. Intermediate values are kept unrounded; the displayed result is rounded for readability.

What does the Pump input power calculator calculate?

Estimate pump input power needed to move a fluid through a specified head at a stated efficiency.