How to use this calculator
Estimate indirect splitting tensile strength from diametral load and intact rock-core dimensions.
- Enter Peak diametral load (kN), Rock-core disk diameter (mm), Rock-core disk thickness (mm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Enter the peak diametral load and the measured diameter and disk thickness of the intact rock-core specimen. Keep the load and dimensions in the stated units; the output is an indirect tensile strength estimate for a Brazilian-type splitting test.
Inputs and units
peakLoadKN— Peak diametral load (kN)- Maximum applied load at failure.
diameterMm— Rock-core disk diameter (mm)- Measured specimen diameter.
thicknessMm— Rock-core disk thickness (mm)- Measured disk thickness along the core axis.
Formula
Splitting tensile strength = 2P/(πDL), where P is peak load, D is disk diameter, and L is disk thickness.
Method
Convert peak load from kilonewtons to newtons and dimensions from millimetres to metres, then apply the ASTM D3967 splitting-tensile relation. Since 1 N/mm² equals 1 MPa, the numeric result is directly reported in MPa when load is in N and dimensions are in mm.
Worked example
At 25 kN peak load, a 54 mm diameter and 27 mm thick core gives 10.92 MPa splitting tensile strength.
Assumptions and limits
This calculator reduces supplied test values only. It does not establish specimen preparation, loading rate, platen alignment, validity of diametral failure, anisotropy handling, or project acceptance criteria. Follow the current test method and laboratory procedures.
Frequently asked questions
What is the Brazilian test?
It is an indirect tensile test in which a disk-shaped rock specimen is loaded across its diameter until it splits.
Why is the result in MPa?
Using load in newtons and dimensions in millimetres gives newtons per square millimetre, numerically equal to megapascals.
Does this decide whether the rock is acceptable?
No. Compare results with the project specification and the laboratory’s test-validity rules.
How do I use the Rock Core Brazilian Tensile Strength Calculator?
Enter Peak diametral load (kN), Rock-core disk diameter (mm), Rock-core disk thickness (mm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Rock Core Brazilian Tensile Strength?
At 25 kN peak load, a 54 mm diameter and 27 mm thick core gives 10.92 MPa splitting tensile strength.
Reference: ASTM D3967-23 intact rock-core splitting tensile test method. See our calculation methodology.