How to use this calculator
Fold a real sinusoid into the first Nyquist band for ideal uniform sampling.
- Enter Input sine frequency (Hz), Sampling rate (Hz). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Sampled sinusoid alias frequency explained
For ideal uniform sampling, a real sinusoid appears at the frequency folded into the first Nyquist band. The calculator reports the nonnegative alias magnitude from 0 to half the sampling rate; it does not reconstruct phase or remove aliasing.
Inputs, symbols, and units
f— Input sine frequency (Hz)- Input sine frequency (Hz).
s— Sampling rate (Hz)- Sampling rate (Hz).
Formula and method
f_alias = |f − round(f/f_s) × f_s|, with 0 ≤ f_alias ≤ f_s/2.
Here f is the input frequency and f_s is the sampling rate. The nearest integer number of sample-rate intervals folds the input into the first Nyquist band; sign and phase are not reported.
A worked scenario
Input sine frequency (Hz) = 1700; Sampling rate (Hz) = 1000.
- Sampled sinusoid alias frequency: 300 Hz
This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Assumptions and edge cases
Returns magnitude from 0 to fs/2; phase, filtering, and multiple-signal mixing are excluded.
Frequently asked questions
Can different inputs alias together?
Different continuous-time frequencies can produce the same sampled sequence when they differ by an integer multiple of the sampling rate, subject to phase and sampling assumptions.
Does this remove aliasing?
No. It describes the apparent frequency after ideal sampling; analog filtering or a higher sampling rate is needed to reduce aliasing.
Does phase remain unchanged?
The result is only a nonnegative frequency magnitude. Phase and whether a folded component is spectrally inverted are not calculated.
How do I use the Sampled sinusoid alias frequency calculator?
Enter Input sine frequency (Hz), Sampling rate (Hz). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Sampled sinusoid alias frequency?
Input sine frequency (Hz) = 1700; Sampling rate (Hz) = 1000. Sampled sinusoid alias frequency: 300 Hz This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Read our calculation methodology.