Scalar continuous optimal regulator calculator

Balance state error against actuator effort for a one-state continuous linear plant.

4,000 tools
Scalar continuous optimal regulator calculator — Open-loop rate a (1/s), Actuator coefficient b (state/input/s), State cost q and calculation method
Scalar continuous optimal regulator calculator: inputs and calculation method.

How to use this calculator

Balance state error against actuator effort for a one-state continuous linear plant.

  1. Enter Open-loop rate a (1/s), Actuator coefficient b (state/input/s), State cost q, Input cost r, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Scalar continuous optimal regulator explained

This scalar continuous-time LQR solves the algebraic Riccati equation for x′ = ax + bu with quadratic state and control costs. The feedback gain defines u = −Kx; the reported pole and cost describe the closed-loop model.

Inputs, symbols, and units

a — Open-loop rate a (1/s)
State coefficient in x′=a x+b u.
b — Actuator coefficient b (state/input/s)
Nonzero input effectiveness.
q — State cost q
Positive coefficient of x squared in the cost.
r — Input cost r
Positive coefficient of u squared in the cost.
x — Initial state
State used to report the minimized cost.

Formula and method

0=2aP−b²P²/r+q; K=bP/r; u=−Kx; Jmin=P x₀².

Use the stabilizing nonnegative Riccati solution. Cost weights must be expressed with consistent state and input units before comparing designs.

A worked scenario

Open-loop rate a (1/s) = 0.8; Actuator coefficient b (state/input/s) = 1.2; State cost q = 3; Input cost r = 0.7; Initial state = 2.

  • Optimal feedback gain: 2.841559 input/state
  • Closed-loop pole: -2.609871 1/s
  • Minimum infinite-horizon cost: 6.630305 cost

An unstable rate 0.8/s with input effectiveness 1.2 uses state cost 3 and input cost 0.7; evaluate the optimal cost from state 2.

Assumptions and edge cases

Unconstrained full-state feedback, no delay, one state and positive weights. Real actuator saturation changes the optimum.

Reading the outputs

Gain specifies the negative-feedback law; the closed-loop pole must be negative; minimum cost includes the whole future trajectory.

Frequently asked questions

What happens when input cost rises?

Control effort is penalized more strongly, generally reducing aggressive feedback.

Can b be negative?

Yes; the gain sign then follows the actuator sign.

Is the minimum cost a physical energy?

Only if your chosen weights make that interpretation appropriate.

How do I use the Scalar continuous optimal regulator calculator?

Enter Open-loop rate a (1/s), Actuator coefficient b (state/input/s), State cost q, Input cost r, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Scalar continuous optimal regulator?

Open-loop rate a (1/s) = 0.8; Actuator coefficient b (state/input/s) = 1.2; State cost q = 3; Input cost r = 0.7; Initial state = 2. Optimal feedback gain: 2.841559 input/state Closed-loop pole: -2.609871 1/s Minimum infinite-horizon cost: 6.630305 cost An unstable rate 0.8/s with input effectiveness 1.2 uses state cost 3 and input cost 0.7; evaluate the optimal cost from state 2.