How to use this calculator
Calculate capacitance, electrode charge, and individual electric fields across dielectric layers stacked between parallel plates.
- Enter Electrode overlap area (cm^2), Layer thicknesses (mm), Matching relative permittivities, Applied voltage (V). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Series dielectric layer capacitor fields explained
The example uses two series layers, 0.2 and 0.4 mm thick, with relative permittivities 2.5 and 4. The normal displacement is shared, while voltage divides according to each layer’s thickness and permittivity.
Inputs, symbols, and units
A— Electrode overlap area (cm^2)- Common electrode overlap area in cm², not m². The model converts it to square metres.
d— Layer thicknesses (mm)- Positive thickness of each series-stacked dielectric layer, in millimetres. Use comma-separated values in the stated order.
er— Matching relative permittivities- Positive relative permittivity for each matching layer, a dimensionless ratio to vacuum permittivity. Use comma-separated values in the stated order.
V— Applied voltage (V)- Applied voltage (V). This is a dimensionless model parameter unless the label explicitly states a unit.
Formula and method
C=ε0A/Σ(di/εri); D=Q/A; Ei=D/(ε0εri); Vi=Ei di.
The same normal electric displacement passes through every ideal layer because internal interfaces have no free charge. Voltage drops add across the stack. Area converts from square centimetres and thickness from millimetres to SI units.
A worked scenario
Electrode overlap area (cm^2) = 25; Layer thicknesses (mm) = 0.2,0.4; Matching relative permittivities = 2.5,4; Applied voltage (V) = 120.
- Equivalent layered capacitance: 122.97483082 pF
- Free electrode charge: 14.7569797 nC
- Stored electrostatic energy: 8.85418782e-07 J
- Layer field strengths: 0.26666667, 0.16666667 kV/mm
- Voltage drops in layer order: 53.33333333, 66.66666667 V
The two layers have different thickness and permittivity. Their voltage drops need not be proportional to thickness alone, because the electric field differs by permittivity.
Assumptions and edge cases
Parallel plates with negligible fringing, linear isotropic dielectrics, and no free interfacial charge. No leakage, breakdown, field-dependent permittivity, or dielectric losses are evaluated.
Reading the outputs
Layer fields are kV/mm and voltage drops follow input order. Summing those drops should recover the signed applied voltage.
Frequently asked questions
Does the higher-permittivity layer have higher field?
For equal displacement, its electric field is lower.
Can this check dielectric breakdown?
No. Compare a validated field model with appropriate material data separately.
Are layers side by side?
No. They are stacked along the field direction, forming a series dielectric arrangement.
How do I use the Series dielectric layer capacitor fields calculator?
Enter Electrode overlap area (cm^2), Layer thicknesses (mm), Matching relative permittivities, Applied voltage (V). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Series dielectric layer capacitor fields?
Electrode overlap area (cm^2) = 25; Layer thicknesses (mm) = 0.2,0.4; Matching relative permittivities = 2.5,4; Applied voltage (V) = 120. Equivalent layered capacitance: 122.97483082 pF Free electrode charge: 14.7569797 nC Stored electrostatic energy: 8.85418782e-07 J Layer field strengths: 0.26666667, 0.16666667 kV/mm Voltage drops in layer order: 53.33333333, 66.66666667 V The two layers have different thickness and permittivity. Their voltage drops need not be proportional to thickness alone, because the electric field differs by permittivity.
Background or definition reference: NIST 2022 CODATA constants.
Read our calculation methodology.