CalcWorldHub
Free online calculator · no signup

Two state sensor observability calculator

Determine whether a chosen scalar sensor contains enough information to reconstruct both model states.

4,000 tools
Two state sensor observability calculator — A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s) and calculation method
Two state sensor observability calculator: inputs and calculation method.

How to use this calculator

Determine whether a chosen scalar sensor contains enough information to reconstruct both model states.

  1. Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Two state sensor observability explained

Observability determinant1mixed state units
Observability determinant: 1 mixed state units in the worked scenario.

A numerical walkthrough

A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; C1 (output/state 1) = 1; C2 (output/state 2) = 0.

  • Observability determinant: 1 mixed state units
  • Smallest singular value: 1 scaled units
  • Largest singular value: 1 scaled units

A position-only measurement C=(1,0) observes the default position-and-rate plant through its coupling.

The model behind the numbers

O=[C; CA]. A nonzero determinant means two initial state components can be distinguished from ideal output history.

The first row is immediate sensor sensitivity and the second is its dynamic evolution. Test sensor placement before assigning observer poles.

What to enter

a — A11 (1/s)
First row, first column of the state matrix.
b — A12 (state 1/state 2/s)
Contribution of state two to the time derivative of state one.
c — A21 (state 2/state 1/s)
Coupling from the first state into the second derivative.
d — A22 (1/s)
Second row, second column of the state matrix.
h — C1 (output/state 1)
Sensor sensitivity to the first state.
k — C2 (output/state 2)
Sensor sensitivity to the second state.

Interpreting the result

Local linear observability does not imply reliable nonlinear estimation, and noise can make weak directions practically unusable.

Reading the outputs

The determinant and singular values describe this particular state and sensor scaling; they are not measurement-noise estimates.

Frequently asked questions

Can one sensor observe two states?

Yes, when the dynamics transfer information between them.

Does the actuator vector enter this test?

No. Observability uses A and C.

Can scaling fix a truly unobservable mode?

No; nonsingular scaling cannot change the exact rank.

How do I use the Two state sensor observability calculator?

Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Two state sensor observability?

A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; C1 (output/state 1) = 1; C2 (output/state 2) = 0. Observability determinant: 1 mixed state units Smallest singular value: 1 scaled units Largest singular value: 1 scaled units A position-only measurement C=(1,0) observes the default position-and-rate plant through its coupling.