CalcWorldHub
Free online calculator · no signup

U-chart control limits calculator

Calculate variable three-sigma limits for defects per inspection unit when sample sizes differ. Enter your values to see the result and method.

A better way to figure it out
Clear
inputs.
QC
Clear result · useful details
Free calculatorNo signup ✓

Related calculators

Browse all quality-control calculators →

U-chart control limits calculator — Total defects in each sample, Units inspected in each sample and calculation method
U-chart control limits calculator: inputs and calculation method.

How to use this calculator

Calculate variable three-sigma limits for defects per inspection unit when sample sizes differ.

  1. Enter Total defects in each sample, Units inspected in each sample. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Free calculator guide

When to use this measure

Calculate variable three-sigma limits for defects per inspection unit when sample sizes differ. It is useful when a team needs to calculate u-chart limits with varying sample sizes. This page’s result is distinct from the neighboring tools linked above because it applies the method described here to the stated inputs.

Illustrative U-chart limits and sample ratesDefect-rate points are compared with a center line and upper and lower control limits that narrow as subgroup sizes increase. This is a conceptual sketch, not a calculator result.UCLᵢūLCLᵢdefects per unitsubgroup, n increasing →
Illustrative U-chart: sample defect rates are compared with a center line and subgroup-size-specific limits; the sketch is conceptual, not a calculated result.

What each input means

The required inputs are Total defects in each sample; Units inspected in each sample. Use matching inspection periods and consistent definitions if comparing results over time.

Formula and worked example

ū = Σ defects / Σ units; limitsᵢ = ū ± 3√(ū / nᵢ), LCL ≥ 0

The example has 44 defects over 550 units, so ū = 0.08 defects per unit; each sample gets limits based on its own n.

The example derives a defects-per-unit average and sample-specific three-sigma limits from the stated inspection counts; it is illustrative, not an acceptance target.

Assumptions and interpretation

Enter matching comma-separated lists of nonnegative counts. The method assumes comparable units and a count model; it does not handle over-dispersion automatically.

The limits describe expected count variation under this u-chart model; they are not specification limits. Investigate points outside the limits, then assess product requirements separately.

Reference: NIST/SEMATECH e-Handbook, u control charts.

Frequently asked questions

Why use a u-chart instead of a c-chart?

A u-chart adjusts its limits when the number of inspected units changes; a c-chart expects a constant opportunity.

Why do the limits differ by sample?

The standard error depends on sample size, so smaller samples have wider limits.

Can the lower limit be negative?

The mathematical expression can be negative, but the chart’s lower count limit is set to zero.

How do I use the U-chart control limits calculator?

Enter Total defects in each sample, Units inspected in each sample. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of U-chart control limits?

ū = Σ defects / Σ units; limitsᵢ = ū ± 3√(ū / nᵢ), LCL ≥ 0 The example has 44 defects over 550 units, so ū = 0.08 defects per unit; each sample gets limits based on its own n. The example derives a defects-per-unit average and sample-specific three-sigma limits from the stated inspection counts; it is illustrative, not an acceptance target.