CalcWorldHub
Engineering · CalcWorldHub

555 Monostable Pulse Duration: Timing a One-Shot

A 555 monostable produces one timed output pulse after a valid trigger. For R=100 kΩ and C=10 µF, the ideal pulse is ln(3)RC, about 1.099 seconds. Use the calculator to estimate pulse duration, then account for trigger conditions, component tolerance, and the timer’s real thresholds before treating the result as a finished design.

Open calculator
A one-shot trigger starts one output pulse as the timing capacitor rises to its threshold.

Share this article

A clean trigger edge starts one output pulse, which ends when the capacitor reaches the upper threshold.
The trigger starts the one-shot; the capacitor threshold ends it.

How a one-shot pulse is timed

In a standard 555 monostable, a trigger below roughly one-third of the supply sets the internal latch and turns the output on. The timing capacitor begins near zero and charges through R toward the supply. When its voltage reaches roughly two-thirds of the supply, the threshold comparator resets the latch, the output returns low, and the discharge transistor resets the capacitor.

Those nominal threshold fractions define the ideal timing equation. The trigger starts the interval; the resistor and capacitor determine its duration. This calculator estimates that interval for the conventional one-resistor, one-capacitor arrangement. It does not model a retriggerable timing sequence, a capacitor that starts at a different voltage, or a circuit with additional timing components.

Match the entries to the physical components

The timing resistance field is in kilohms and the timing capacitance field is in microfarads. Enter R=100 for a 100 kΩ resistor and C=10 for a 10 µF capacitor. Both values must be positive. The timer’s supply voltage is not an input because it cancels from the ideal ratio between the charging excursion and the threshold.

A resistor marked in megohms must be converted to kilohms before entry: 1 MΩ is 1,000 kΩ. A capacitor marked in nanofarads must be converted to microfarads: 1,000 nF is 1 µF. Read component markings carefully, especially for small ceramic capacitors where code values and tolerance may not be obvious.

Convert the RC product into pulse duration

For a capacitor charging from zero toward the supply, V_C(t)=V_S(1−e^(−t/RC)). Set V_C to two-thirds of V_S: 2/3=1−e^(−t/RC), so e^(−t/RC)=1/3 and t=ln(3)RC. The calculator converts kΩ to Ω and µF to F before multiplying.

The logarithmic factor is about 1.0986, so the pulse is slightly longer than the raw product RC. With 100 kΩ and 10 µF, RC equals 1 second and the ideal pulse is about 1.0986 seconds. This is a direct consequence of exponential charging; using t=RC alone would underestimate the interval by about 9.9%.

Changing R or C by the same percentage changes the ideal pulse by that percentage. Doubling C while keeping R fixed doubles pulse duration. That makes the relation easy to use for a first component choice, but it also means a 10% capacitor tolerance can produce roughly a 10% timing change before other circuit effects are considered.

Worked examples

A one-second-class pulse

Inputs: R=100 kΩ and C=10 µF.

Calculation: t=ln(3)×100,000 Ω×10×10⁻⁶ F=1.098612 s.

The ideal pulse lasts about 1.099 s after a valid trigger.

A shorter pulse

Inputs: R=47 kΩ and C=4.7 µF.

Calculation: RC=47,000×4.7×10⁻⁶=0.2209 s; t=ln(3)RC=0.242683 s.

The ideal one-shot duration is about 243 ms. A measured prototype may differ within the component and timer tolerances.

The timing capacitor rises exponentially from zero to two-thirds of the supply during the output pulse.
The ln(3) factor comes from charging to two-thirds of the supply.

Interpret the output and timing origin

The result is the approximate time the output remains active after the triggering event, not the delay before a trigger arrives and not the repetition period of a stream of triggers. To create repeated pulses, the next trigger must satisfy the timer’s input requirements and arrive when the circuit can respond.

A trigger held low or allowed to bounce can cause behavior that differs from a clean one-shot event. A practical circuit may need a pull-up, switch debouncing, pulse conditioning, or a minimum retrigger interval. Those functions are outside the two-field timing calculation and should be checked in the schematic and device datasheet.

Tolerances and limits of the ideal estimate

The estimate assumes nominal one-third and two-thirds comparator thresholds, a capacitor initially discharged, negligible leakage, and an ideal resistor-capacitor charge path. Actual pulse width is affected by R and C tolerance, capacitor leakage, timer input currents, threshold variation, supply bypassing, temperature, and layout. A very large resistance or leaky capacitor can make the timing error especially noticeable.

Bipolar NE555 and CMOS variants differ in input current, supply range, output drive, and timing behavior. Check the selected device’s operating conditions and data sheet; a nominal RC value does not establish suitability for every timer.

Verify a pulse on the bench

For a prototype, observe the output with an oscilloscope or logic analyzer and measure from the accepted trigger edge to the output transition that ends the pulse. If the measured pulse is consistently long or short, verify R and C first and compare the capacitor voltage ramp with the nominal two-thirds threshold.

If widths vary, inspect trigger noise, switch bounce, reset-pin behavior, supply decoupling, and whether the capacitor fully resets between events. Record the trigger definition and measurement setup. Critical timing needs design margin and device-specific verification.

Sources and further reading

Share this article

Browse all articles · Calculator: 555 monostable pulse duration calculator