What output compliance means here
An amplifier can be commanded to produce a voltage but still fail to deliver that voltage to a connected load. The output stage has finite drive capability, and current through a load creates a voltage drop across effective output resistance. The calculator represents those effects for one ground-referenced resistor and reports loaded output voltage, load current, and load power.
This static model does not identify a device or predict swing-vs-current, foldback, thermal protection, distortion, or transient recovery. Treat its limits as scenario inputs, then compare them with the chosen amplifier’s specifications.
Apply the output-load model in order
The requested output Vs is first clipped symmetrically to ±Rail. The model then calculates the current that would flow through the series combination Ro + Rl: Iideal = Vcommand/(Ro + Rl). That value is clipped to the interval from −Ilim to +Ilim. Finally, the load voltage is VL = I Rl and load power is PL = I² Rl. Ro and Rl are in ohms, while voltages are in volts, current in amperes, and power in watts.
The order matters. A rail limit changes the command before the load divider is evaluated; a current limit then changes the current; the load voltage is calculated from the limited current. The unloaded command is not the same as the loaded voltage. With Ro = 0 and no active limits, the load receives the command. With a nonzero Ro, some voltage is dropped internally even when the current remains below Ilim.
Worked examples
The output current limit reduces load voltage
Inputs: Vs = 5 V, Ro = 2 Ω, Rl = 100 Ω, Ilim = 0.025 A, Rail = 12 V.
Calculation: Iideal = 5/(2 + 100) = 0.04902 A, so I = 0.025 A. VL = 0.025 × 100 = 2.5 V; PL = 0.025² × 100 = 0.0625 W.
The 25 mA limit is active, so the 100 Ω load receives 2.5 V rather than the requested 5 V.
A rail-clamped command with a lighter load
Inputs: Vs = 9 V, Ro = 10 Ω, Rl = 470 Ω, Ilim = 0.02 A, Rail = 8 V.
Calculation: Vcommand = 8 V. I = 8/(10 + 470) = 0.016667 A. VL = 0.016667 × 470 = 7.8333 V; PL ≈ 0.13056 W.
The command is rail-limited, but the current remains under 20 mA; the 10 Ω model output resistance accounts for the load-voltage drop.
Separate voltage swing from current limit
A lower load resistance draws more current for the same command. It can therefore trigger the current limit before the modeled swing limit. A larger resistance draws less current but may still see less than the requested voltage because Ro is in series. The load’s power depends on the voltage actually reaching it, not on the unloaded command alone. Use the reported current and power to check the consequences of a proposed resistor value.
The model assumes symmetric voltage and current limits. Real outputs may source and sink differently, and swing is often specified at a particular load. Use those conditions instead of treating Rail as universal; capacitive or nonlinear loads need a dynamic analysis.
Check two resistor-load cases
In the first case, the current demanded by the command exceeds the available limit, so the load receives less than the requested voltage. In the second, the command is first clipped to the selected rail; current then remains below the chosen current limit and the series output resistance creates the remaining drop.
Choose limits from a real amplifier specification
For hardware, check output swing at the intended supply and load current, plus continuous current and thermal limits. A short-circuit figure may describe protection rather than a precise operating rating. Feedback resistors can also draw current; capacitance changes stability.
Do not raise Ilim just to produce a desired result. Use the output-compliance calculator to see which idealized cap is active, then verify the circuit against the selected device’s data sheet.
Verify with load measurements
Measure voltage across the load and its current at the same operating point. For a resistor, compare I with VL/Rl and power with VL²/Rl. An unloaded output is a different condition; repeat for both polarities if the application uses them.
A lower measured voltage can reflect swing, current limiting, supply sag, series resistance, or wiring. Confirm load value and units before investigating power. The model does not determine temperature or safe operating area.