What the result represents
Axial elongation is the change in length along a member’s axis caused by a tensile force. Under a uniform, linearly elastic model, the displacement is proportional to force and length and inversely proportional to Young’s modulus and area. The result is a small-deformation estimate for a straight, prismatic member, rather than a prediction of every point’s movement in an assembled structure.
The model treats the cross-section and material response as uniform over the entered length. It does not add grip motion, connection slip, bending, local strain around holes, temperature change, plasticity, or load sharing with other members.
Match each field to the member
Enter axial force in kilonewtons, member length in metres, Young’s modulus in gigapascals, and area in square millimetres. The runtime accepts nonnegative values for force and length and requires positive modulus and area. A zero force or zero length therefore returns zero; a zero material modulus or area is not a usable model. The force input is a magnitude, so the result is reported as a positive elongation estimate.
Use the area perpendicular to the member’s axis at the section being checked. For a circular solid bar, area is πd²/4; for a rectangular bar, multiply width by thickness. If the member has holes or a reduced section, decide whether a single uniform area is reasonable. A tapered bar or stepped bar requires adding segment deformations rather than entering one convenient average without justification.
Formula and unit conversion
The calculation is δ = PL/(AE): P is axial force, L is the loaded length, A is cross-sectional area, and E is Young’s modulus. With SI base units, P is newtons, L is metres, A is square metres, and E is pascals; the quotient is metres. The page accepts kN, GPa, and mm², converts them internally, then converts the displacement from metres to millimetres for display.
For the opening case, 20 kN is 20,000 N, 500 mm² is 0.0005 m², and 200 GPa is 200 billion Pa. Thus δ = 20,000 × 2 /(0.0005 × 200×10⁹) m = 0.0004 m = 0.4 mm. Keep the powers of ten visible: treating mm² as m² or GPa as Pa changes the answer by many orders of magnitude.
Two numerical checks
For a second hypothetical tie, use P = 35 kN, L = 2.4 m, E = 70 GPa, and A = 600 mm². Converting gives 35,000 × 2.4 /(0.0006 × 70×10⁹) = 0.002 m, or 2 mm. This arithmetic check is not a material certification; it simply confirms the calculator’s unit conversions for the selected values.
Keep force, length, and material fixed but increase the area from 600 to 1,200 mm²: the ideal extension halves from 2 mm to 1 mm. If instead length doubles while the other three inputs stay fixed, extension doubles. These proportional checks are useful when a result feels implausible, because they test the structure of the formula without needing a second reference value.
When a single EA model is not enough
The compact equation assumes constant axial force, area, and modulus along the member. For segments in series, calculate δᵢ = P Lᵢ/(AᵢEᵢ) for each segment and add their signed changes. If axial force varies with position, the more general calculation integrates N(x)/(A(x)E(x)) over the length. A thermal extension term or a support constraint must be handled separately.
The estimate is not a strength check. A small extension does not prove that stress is below yield or an allowable value, and a calculated elongation does not establish stability against buckling. Stress concentrations, eccentricity, fatigue, joints, and restraint conditions need their own models. For design, use the applicable material data and engineering procedure; this result alone is not approval.
A practical verification routine
Before trusting a result, sketch the member and mark the force direction, the length between its effective load points, and the section that carries the load. Confirm that the input modulus corresponds to the material condition and direction, particularly for composites, wood, or processed materials. Then calculate δ in base SI units and convert metres to millimetres only at the end.
Compare with an independent stiffness check when possible: axial stiffness is EA/L, so displacement should equal force divided by that stiffness. If a test measurement differs, inspect gauge length, fixture compliance, area changes, temperature, and load alignment before changing the material modulus to force a match.
Worked examples
A uniform steel-like bar model
Inputs: Force = 20 kN; length = 2 m; Young’s modulus = 200 GPa; area = 500 mm².
Calculation: δ = PL/(AE) = (20,000 × 2)/(0.0005 × 200×10⁹) m = 0.0004 m.
Estimated axial elongation = 0.4 mm under the uniform linear-elastic assumptions.
A longer aluminum-like tie check
Inputs: Force = 35 kN; length = 2.4 m; Young’s modulus = 70 GPa; area = 600 mm².
Calculation: δ = (35,000 × 2.4)/(0.0006 × 70×10⁹) m = 0.002 m.
The model gives 2 mm extension; doubling area alone would halve it to 1 mm.