Why the root controls this ideal case
A cantilever is fixed at one end and free at the other. A transverse point load at the free tip has its full lever arm at the fixed root, so the bending-moment magnitude there is P times L. Moving toward the free end, the moment decreases linearly and is zero at the load point in the idealized member. The maximum nominal bending stress therefore occurs at the root section for this one-load case.
The calculator returns an elastic extreme-fibre stress estimate based on that root moment and a section modulus. It does not calculate a stress concentration around a clamp, bolt, notch, weld, or abrupt change in shape. Those local effects can make peak stress differ from the nominal value even when the global beam calculation is correct.
Use the matching section modulus
Tip load P is entered in newtons, the cantilever length L in metres, and section modulus S in cubic centimetres. The runtime accepts a nonnegative load and length and requires S > 0. It reports MPa to five decimal places. The field represents the elastic section modulus I/c for the relevant bending axis, not a plastic modulus or an unrelated strength value from a catalogue.
Section modulus depends on both section geometry and axis. A rectangular section has a different modulus when rotated because the bending depth changes. For an asymmetric section, use the appropriate extreme fibre on the side being checked; the calculator uses one positive S and does not distinguish separate top and bottom moduli. If a source gives S in mm³, divide by 1,000 to enter cm³.
Follow the unit conversion
The model first forms M = PL in N·m and uses σ = M/S. Since S is entered in cm³, one unit is 10⁻⁶ m³. Dividing N·m by cm³ therefore gives pascals after the volume conversion, and dividing that Pa value by 10⁶ to report MPa cancels the 10⁻⁶ factor. Numerically, with these specific input units, σ(MPa) = P(N) × L(m) ÷ S(cm³).
That compact numerical relation is unit-specific. If P is supplied in kN, L in millimetres, or S in mm³, convert the quantities first or derive the scale factor again. Treating 100 cm³ as 100 m³ or placing a section inertia in the section-modulus field can produce a result off by many orders of magnitude. Confirm that the calculator’s labels match the data source before trusting the output.
Two worked checks
For P = 500 N, L = 2 m, and S = 100 cm³, the root moment is 500 × 2 = 1,000 N·m. The stress is 1,000 ÷ (100 × 10⁻⁶) = 10,000,000 Pa = 10 MPa. The default values reproduce this check. If the same 500 N load were applied only 1 m from the fixed face, the ideal moment and nominal stress would both be half as large, though that is a different load location from the tip case.
For P = 750 N, L = 1.2 m, and S = 75 cm³, M = 900 N·m and σ = 900 ÷ (75 × 10⁻⁶) = 12,000,000 Pa, or 12 MPa. The calculator’s direct numeric relation gives 750 × 1.2 ÷ 75 = 12 MPa. Repeating the dimensional conversion independently is useful because a correct displayed number can otherwise hide an incorrect choice of section axis.
Worked examples
500 N at the tip of a 2 m cantilever
Inputs: P = 500 N, L = 2 m, S = 100 cm³.
Calculation: Mroot = 500 × 2 = 1,000 N·m; σ = 1,000 ÷ (100 × 10⁻⁶) Pa = 10 MPa.
The modeled nominal root stress is 10.00000 MPa.
750 N at a 1.2 m lever arm
Inputs: P = 750 N, L = 1.2 m, S = 75 cm³.
Calculation: Mroot = 750 × 1.2 = 900 N·m; σ = 900 ÷ (75 × 10⁻⁶) Pa = 12 MPa.
The nominal root stress is 12.00000 MPa before any design resistance comparison.
Separate stress from strength
Section modulus describes gross geometry; it does not capture local peak stress at a clamp, bolt hole, notch, weld, or abrupt section change. Keep the PL root-moment estimate separate from those local-detail checks, and resolve any axial component of an angled force in its own model.
Verify a practical setup
Record the measured distance from the fixed face to the load line, not simply the stock length of the beam. Check whether the force is a static service value or a factored design value, and avoid mixing the two. Find S for the same orientation and extreme-fibre convention as the actual member. Then calculate PL and divide by S with units carried through before comparing with a material or design resistance.
The model assumes a prismatic member, linear-elastic bending, a static transverse end load, a rigid fixed support, and the correct section modulus. It omits shear, local bearing, buckling, torsion, fatigue, dynamic effects, and stress concentration. Flexible fixtures or an eccentric load can change the response.