Cantilever Root Moment from a Tip Load

A 500 N force applied 2 m from a cantilever’s fixed support creates a 1,000 N·m root moment in the ideal static model. This calculator is a load-times-distance calculation, but the support condition and load location matter: the same force at the center of a simply supported span produces a different maximum moment. Use the guide to identify the lever arm and avoid treating the output as a complete beam analysis.

Open calculator
A cantilever fixed at the wall has a downward force at its free tip, a full-span lever arm, and a curved moment arrow at the root.

Share this article

A cantilever fixed at the wall has a downward force at its free tip, a full-span lever arm, and a curved moment arrow at the root.
The fixed root carries the maximum moment for this end-load case.

Locate the maximum bending moment

For a straight cantilever fixed at one end, a point load at the free tip has a moment arm equal to the full cantilever length. Taking moments about the fixed root gives Mroot = P × L. The bending-moment magnitude is largest at the root and falls linearly to zero at the free end, where the point load is applied. This is the static equilibrium pattern assumed by the calculator.

The tool takes only two inputs: tip-load magnitude in newtons and cantilever length in metres. It accepts nonnegative values, including zero, and returns N·m to five decimal places. It does not ask for a material or cross-section because those quantities are not needed to calculate the external bending moment for this ideal case. They become necessary for stress, deflection, or capacity checks.

Measure the lever arm correctly

L is the distance along the beam from the root section to the line of action of the tip force. Use the unsupported cantilever length, not a full assembly dimension that includes a wall plate or hidden support depth. If the load acts through a bracket beyond the beam end, its offset may increase the moment arm; that eccentricity is not represented by entering a different beam span unless the geometry is modeled consistently.

P is the load perpendicular to the beam axis for this bending case. An axial force does not create the same bending moment, and a force at an angle has a transverse component that should be resolved before entering it. The runtime uses a nonnegative magnitude and does not preserve a clockwise or counterclockwise sign. State the chosen direction separately if moment sign is important in a larger analysis.

Carry the units through equilibrium

A newton multiplied by a metre gives a newton-metre, the unit of bending moment. For example, P = 500 N and L = 2 m give M = 500 × 2 = 1,000 N·m. If a source reports force in kilonewtons, multiply by 1,000 to get newtons. If the arm is in millimetres, divide by 1,000 to convert to metres before multiplying so the result remains in N·m.

N·m is the bending-moment unit here, not a force unit. A report in kN·m uses a value 1,000 times smaller than the same moment in N·m. Keep intermediate precision and round only to match measured input precision.

Two worked checks

For P = 500 N at a 2 m arm, the root moment is 1,000 N·m. A static free-body check gives an equal opposing reaction moment at the support. If the force is doubled to 1,000 N while the length remains 2 m, the result becomes 2,000 N·m; if instead the force stays at 500 N and the arm is 1 m, the result is 500 N·m. These comparisons show direct proportionality to either input.

For P = 750 N and L = 1.5 m, Mroot = 750 × 1.5 = 1,125 N·m, which is 1.125 kN·m. A second check can be made from the work-equivalent units: 0.75 kN × 1.5 m = 1.125 kN·m. Agreement confirms the kilo conversion. Do not multiply a kN value by a millimetre value and then label the numerical result N·m without converting both units.

Worked examples

500 N at a 2 m cantilever tip

Inputs: P = 500 N and L = 2 m.

Calculation: Mroot = P × L = 500 × 2 = 1,000 N·m.

The maximum ideal bending-moment magnitude is 1,000.00000 N·m at the fixed root.

750 N over a 1.5 m lever arm

Inputs: P = 750 N and L = 1.5 m.

Calculation: Mroot = 750 × 1.5 = 1,125 N·m = 1.125 kN·m.

The calculator reports 1,125.00000 N·m before any stress or capacity check.

A 500 newton tip force with a 2 metre lever arm produces a root moment of 1,000 newton-metres.
Convert the arm to metres and the force to newtons before multiplying.

Compare support and load arrangements

A simply supported beam with a centered point load has maximum moment PL/4 because the reactions share the load and the diagram peaks at midspan. A cantilever with a tip force has root moment PL. With the same P and L, these ideal maxima differ by a factor of four because the support and load cases differ.

A full-span uniform load has a different root moment: wL²/2. Multiplying its total force wL by L would double that result. This calculator is only for a single tip force; use a load-case-specific analysis for distributed loads, multiple forces, or applied couples.

What the moment does and does not tell you

The output is moment demand; it does not include section modulus, stress, deflection, resistance, fasteners, bearing, shear, torsion, fatigue, dynamics, or load combinations. Equal moments can produce different stresses and movement in members with different geometry, materials, and restraint.

Confirm the force is transverse and at the free end, measure the effective arm, then recalculate P×L. Use a full analysis for other loads or supports. For stress, add the correct section modulus; for movement, use E and I in a deflection relation. Neither result is inferred by this calculator.