Cantilever Tip Deflection from an End Load

A 1,000 N end load on a 2 m cantilever with E = 200 GPa and I = 800 cm⁴ gives about 1.66667 mm tip deflection in the small-deflection beam model. The calculator describes one elastic case: a uniform member fixed at the root and loaded at its free end. It is not the same as a beam under distributed load, and a plausible number still depends on accurate stiffness and support assumptions.

Open calculator
A fixed cantilever with a point force at the free end bends along a deflected curve, with vertical tip movement marked.

Share this article

A fixed cantilever with a point force at the free end bends along a deflected curve, with vertical tip movement marked.
The largest displacement for this ideal end-load case occurs at the free tip.

Understand the support and load position

The cantilever is fixed against rotation and vertical movement at one end, with a transverse point force applied at the opposite tip. Under those conditions, the free end has the greatest deflection. The equation is δtip = PL³/(3EI). It is the classical Euler–Bernoulli result for a uniform prismatic beam with small elastic bending, not a general solution for every bracket, shelf, or projecting member.

The calculator labels the force End load (N) and the length Cantilever length (m). It accepts a nonnegative force, requires positive length, modulus, and second moment, and returns millimetres to five decimal places. The runtime treats zero load as zero movement. For an inclined force, use the transverse component for this bending relation; an axial component causes a different response.

Convert E and I before evaluating the formula

Young’s modulus E is entered in gigapascals and converted to pascals by multiplying by 10⁹. The area second moment I is entered in cm⁴ and converted to m⁴ by multiplying by 10⁻⁸. For example, 800 cm⁴ is 8 × 10⁻⁶ m⁴. Keeping L in metres and P in newtons makes the equation’s result metres; the calculator multiplies it by 1,000 to display millimetres.

Use an E value appropriate to the material and direction of loading. For anisotropic materials, a single modulus may not describe the response in every orientation. Use I about the neutral axis for the actual bending direction; do not substitute polar moment, mass inertia, or a section modulus. An I value read from a product table must match the member orientation and units before entry.

Read the cubic length effect

Deflection is proportional to P and L³, and inversely proportional to E and I. Doubling the example span from 2 m to 4 m makes the result eight times larger, about 13.33333 mm. Doubling P also doubles movement; doubling I halves it. This scaling is a quick reasonableness check.

PL³ has units N·m³ and EI has units N·m², so the ratio is metres. If a hand calculation produces centimetres before the final conversion, check the units. Keep precision through the calculation rather than rounding E or I early.

Two worked checks

For P = 1,000 N, L = 2 m, E = 200 GPa, and I = 800 cm⁴, convert E = 200 × 10⁹ Pa and I = 8 × 10⁻⁶ m⁴. Then δ = 1,000 × 2³ ÷ [3 × 200 × 10⁹ × 8 × 10⁻⁶] = 0.0016666667 m. Multiplying by 1,000 gives 1.6666667 mm, displayed as 1.66667 mm.

For P = 600 N, L = 1.5 m, E = 70 GPa, and I = 3,000 cm⁴, use I = 3 × 10⁻⁵ m⁴. The numerator is 600 × 1.5³ = 2,025 N·m³; the denominator is 3 × 70 × 10⁹ × 3 × 10⁻⁵ = 6,300,000 N·m². The ratio is 0.0003214286 m or 0.3214286 mm, so the tool displays 0.32143 mm.

Worked examples

1,000 N on a 2 m cantilever

Inputs: P = 1,000 N, L = 2 m, E = 200 GPa, I = 800 cm⁴.

Calculation: δtip = 1,000 × 2³ ÷ [3 × (200 × 10⁹) × (800 × 10⁻⁸)] × 1,000 = 1.66667 mm.

The modeled free-end deflection is 1.66667 mm.

A shorter beam with different stiffness

Inputs: P = 600 N, L = 1.5 m, E = 70 GPa, I = 3,000 cm⁴.

Calculation: δtip = 600 × 1.5³ ÷ [3 × (70 × 10⁹) × (3,000 × 10⁻⁸)] × 1,000 = 0.32142857 mm.

The full-precision estimate is 0.32142857 mm; the calculator displays 0.32143 mm.

A 1,000 newton end load on a 2 metre beam with E 200 gigapascals and I 800 centimetres to the fourth gives 1.66667 millimetres tip movement.
The calculator converts the SI equation from metres to millimetres.

Keep this case separate from distributed loading

An end force is not interchangeable with a uniform load, even when total force is the same. The opening case has a 1,000 N total force; a 500 N/m load across 2 m instead uses wL⁴/(8EI), while the end force uses PL³/(3EI). Different load shapes produce different movement.

The tip value is not the beam’s displacement everywhere. The beam curves along its length and the slope changes from zero at the ideal root to a maximum at the free end. If clearance matters at an intermediate point, use deflection at that location rather than treating the tip output as uniform movement.

Limits and an engineering check

The model assumes a straight uniform beam, linear elasticity, a rigid fixed support, small rotations, and a load at the free tip. It omits shear deformation, fixture movement, connection slip, self-weight unless added separately, local indentation, vibration, creep, and yielding. Short or deep members can depart from the Euler–Bernoulli idealization.

Confirm unsupported length, load direction, modulus, and section I, then recalculate in SI units. Compare direction and movement with the physical setup and apply a relevant serviceability check. This single-load estimate helps compare scenarios; it does not establish whether an installation is safe or stiff enough.