Define the load case before entering values
A uniform load has intensity w, measured as force per unit length. Here the field is N/m, and the model assumes that this intensity acts continuously from the fixed root to the free end. A value of 500 N/m over 2 m represents 1,000 N total distributed load; it is not the same input as a 1,000 N point load at the end. The location and support condition change the deflection equation.
The fixed end restrains both vertical translation and rotation in the ideal model. The free tip is where the largest downward deflection occurs for this load pattern. Uniformity refers to load intensity along the beam, not to uniform deflection or stress. If a real load covers only part of the member, tapers along its length, or is applied through a flexible attachment, this single formula does not represent that distribution.
Read the inputs and convert the section units
Enter distributed load w in N/m and cantilever length L in metres. Young’s modulus E is entered in GPa, while the second moment of area I is in cm⁴. The runtime converts these to pascals and m⁴ internally: E(Pa) = E(GPa) × 10⁹ and I(m⁴) = I(cm⁴) × 10⁻⁸. All four fields must be finite; w may be zero, while L, E, and I must be positive.
Use the modulus for the material and condition being modeled, not a strength value. Obtain I for the correct bending axis and actual section orientation. For a rectangle, rotating the member can change I substantially because the depth is raised to the third power. If a manufacturer reports a section value in mm⁴, divide by 10,000 to convert it to cm⁴; do not copy the number unchanged into the field.
Why length dominates this result
The maximum tip deflection is δtip = wL⁴/(8EI). The fourth power means that the same beam and load intensity at twice the span would have sixteen times the predicted tip movement. In contrast, doubling w doubles deflection, and doubling E or I halves it. This scaling is a useful reasonableness check, but it also means a small span measurement error can matter more than a similar percentage error in load.
With consistent SI units, wL⁴ has units N·m³ and EI has units N·m², leaving metres. The calculator multiplies the metre result by 1,000 and displays millimetres to five decimal places. Keep intermediate values unrounded; converting I from cm⁴ to m⁴ before using the equation avoids an error of eight orders of magnitude.
Two worked checks
For w = 500 N/m, L = 2 m, E = 200 GPa, and I = 800 cm⁴, convert E to 200 × 10⁹ Pa and I to 800 × 10⁻⁸ = 8 × 10⁻⁶ m⁴. Then δ = 500 × 2⁴ ÷ [8 × (200 × 10⁹) × (8 × 10⁻⁶)] = 0.000625 m, or 0.62500 mm. The total load is 1,000 N, which helps distinguish this case from a 1,000 N tip force.
For a shorter, more flexible example, use w = 300 N/m, L = 1.5 m, E = 70 GPa, and I = 2,000 cm⁴. After conversion I = 2 × 10⁻⁵ m⁴. The numerator is 300 × 1.5⁴ = 1,518.75 N·m⁴; the denominator is 8 × 70 × 10⁹ × 2 × 10⁻⁵ = 11,200,000 N·m². The result is 0.0001356027 m, or 0.13560 mm to the calculator’s precision.
Worked examples
500 N/m over a 2 m cantilever
Inputs: w = 500 N/m, L = 2 m, E = 200 GPa, I = 800 cm⁴.
Calculation: δ = 500 × 2⁴ ÷ [8 × (200 × 10⁹) × (800 × 10⁻⁸)] × 1,000 = 0.62500 mm.
The modeled free-end deflection is 0.62500 mm.
A 1.5 m cantilever with a lighter uniform load
Inputs: w = 300 N/m, L = 1.5 m, E = 70 GPa, I = 2,000 cm⁴.
Calculation: δ = 300 × 1.5⁴ ÷ [8 × (70 × 10⁹) × (2,000 × 10⁻⁸)] × 1,000 = 0.13560268 mm.
The full-precision estimate is 0.13560268 mm; the displayed value is 0.13560 mm.
Compare changes without mixing load models
If the span changes from 2 m to 1 m with w, E, and I fixed, predicted deflection falls by sixteen, from 0.625 mm to 0.0390625 mm. If instead w falls from 500 to 250 N/m at the original span, deflection halves to 0.3125 mm. Each comparison changes only one input.
An end force uses PL³/(3EI), not wL⁴/(8EI). A simply supported beam under uniform load also has different boundary conditions and a different coefficient. Do not compare outputs until support type, load pattern, and requested location match.
Use the number as a screening estimate
The formula assumes a uniform prismatic beam, constant elastic properties, a perfectly fixed root, small deflection, and a uniform transverse load over the full span. It omits shear deformation, support movement, local connection rotation, vibration, material nonlinearity, and time effects such as creep. Short, deep, or layered members may not fit the idealization.
Confirm the full-span load intensity and unsupported length, verify E and axis-specific I, and recalculate with consistent units. If movement controls function, compare with the actual serviceability criterion and include support flexibility and other loads. This is one classical beam estimate, not a safe-design decision.