What uniform-load deflection means
For a beam simply supported at its ends with a uniform load w across the entire span, the maximum vertical displacement occurs at midspan for the symmetric case. The relation is δmax = 5wL⁴/(384EI). The calculator reports this displacement in millimeters. w is force per unit length, L is span, E is Young's modulus, and I is the second moment of area about the bending axis.
A uniformly distributed load is not the same as a single total force entered as though it acts at the center. If the total load is W and it is genuinely uniform over span L, then w = W/L. Concentrated loads, triangular loads, partial-span loading, or a changing support condition need a different model or a carefully justified combination of cases.
Convert the calculator's input units
The fields use w in N/m, L in meters, E in gigapascals, and I in cm⁴. The runtime converts E from GPa to Pa by multiplying by 10⁹, converts I from cm⁴ to m⁴ by multiplying by 10⁻⁸, evaluates the formula, and converts the answer from meters to millimeters. Make sure the load intensity refers to the full modeled beam and not to a different tributary width or spacing.
The fourth-power unit conversion is easy to mishandle: 1 cm⁴ = (0.01 m)⁴ = 10⁻⁸ m⁴, not 10⁻⁴ m⁴. Likewise, E = 200 GPa means 200 × 10⁹ Pa. The two conversions multiply together in EI. A useful check is that the formula in base SI units returns meters; multiplying that value by 1,000 gives the displayed millimeters.
Read the scaling before comparing options
With w, E, and I fixed, the predicted displacement varies as L⁴. Increasing span by 10% multiplies this idealized deflection by 1.1⁴, about 1.4641, or roughly 46%. Doubling span makes the result sixteen times larger. Doubling the uniform load doubles deflection, while doubling E or I halves it. These ratios help compare alternatives when the same loading and support assumptions remain valid.
For a rectangular beam, I = bh³/12 when b is the width and h is the depth in the bending direction. The depth has a cubic effect on I, so a modest change in orientation can strongly change the predicted movement. Do not substitute a cross-sectional area for I: area has units m², while second moment of area has units m⁴. The labels in this calculator make that distinction explicit.
Two examples with converted section properties
In the first case, 800 cm⁴ becomes 800 × 10⁻⁸ = 8 × 10⁻⁶ m⁴ and 200 GPa becomes 2 × 10¹¹ Pa. With a 1,000 N/m load over 4 m, the formula gives 0.002083333 m, or 2.08333 mm. The units and order of magnitude are plausible for the stated idealized stiffness, but they do not establish an acceptable serviceability limit.
In the second case, the span and load both change, as do E and I. Converting 20,000 cm⁴ gives 2 × 10⁻⁴ m⁴; 210 GPa is 2.1 × 10¹¹ Pa. The result is about 0.29064 mm. Comparing the answers without examining all changed inputs would hide why the second beam moves less despite its longer span.
Worked examples
Uniform load on a 4 m span
Inputs: w = 1,000 N/m, L = 4 m, E = 200 GPa, I = 800 cm⁴ = 8 × 10⁻⁶ m⁴.
Calculation: 5 × 1,000 × 4⁴ ÷ (384 × 200 × 10⁹ × 8 × 10⁻⁶) = 0.002083333 m = 2.083333 mm.
The calculator displays 2.08333 mm after converting the SI result to millimeters.
A longer, stiffer beam under a larger line load
Inputs: w = 1,500 N/m, L = 5 m, E = 210 GPa, I = 20,000 cm⁴ = 2 × 10⁻⁴ m⁴.
Calculation: 5 × 1,500 × 5⁴ ÷ [384 × (210 × 10⁹) × (20,000 × 10⁻⁸)] = 0.0002906436 m = 0.2906436 mm.
The calculator displays 0.29064 mm. The large I is a key reason this is below the first estimate despite the longer span.
Check the assumed load path and model limits
The expression assumes a prismatic member with constant E and I, simple end supports, small deflection, linear elasticity, and a uniform load over the full clear span. It excludes support settlement and transverse shear deformation, as the calculator's help text states. It also does not add beam self-weight unless the user has already included it in w, and it does not model connection slip, local bearing, vibration, or time-dependent creep.
Before using the estimate, identify whether the entered line load includes the member's own weight, finishes, attached services, and the relevant tributary area. Check whether a design or serviceability limit applies to the structure and load combination. If the member is short or deep, made of a layered or non-prismatic material, or expected to deflect substantially, a simple Euler–Bernoulli result may be inadequate. Use an appropriate engineering analysis for consequential decisions.