CalcWorldHub
Electronics · CalcWorldHub

Diode Voltage Doubler Under Load: Output and Ripple

A simple diode doubler does not hold exactly twice its input once a load draws charge. With a 5 V square-wave drive, 10 mA load, 1 μF flying capacitor, 100 μF reservoir, 100 kHz refresh, 0.30 V per diode and 5 Ω added transfer resistance, this model estimates 9.25 V output and 1 mV peak-to-peak ripple. The result is topology-specific and open-loop.

Open calculator
A flying capacitor transfers charge through a diode path to an output reservoir in a voltage-doubler circuit.

Share this article

A flying capacitor alternates between a charging position and a transfer path that replenishes the output reservoir.
The flying capacitor moves charge to the reservoir once per modeled refresh cycle.

How a flying capacitor raises the output

A voltage doubler alternately charges a flying capacitor and transfers its charge to an output reservoir. In the simplified calculator model, the ideal starting level is twice the zero-to-Vin square-wave amplitude. Two constant diode drops reduce that level, and load current causes an additional voltage drop across an effective output resistance.

The output estimate is Vout ≈ 2Vin − 2Vf − Iout[1/(fsCf) + Rs]. Vin and Vf are volts, Iout is amperes, fs is hertz, Cf and Co are farads, and Rs is ohms. The bracketed term is the model’s effective output resistance: one switching-transfer term plus the entered additional resistance.

Match each field to the assumed circuit

The drive field is a zero-to-Vin square-wave amplitude, not a peak-to-peak sine-wave value or a supply with an assumed negative half-cycle. Vf is the drop per diode, and the formula applies two such drops. Cf is the flying capacitance that transfers charge; Co is the output reservoir that supports the load between refreshes.

The load input is approximately constant DC current. Refresh frequency is the number of charge-transfer cycles per second. Rs combines switch, diode, and capacitor ESR effects into one extra resistance. If the physical circuit has a different topology, multiple stages, a regulated controller, or strongly varying current, this single-resistance model may not represent it.

Work through two loaded estimates

For Vin = 5 V, Vf = 0.30 V, Cf = 1 μF, Co = 100 μF, fs = 100 kHz, Iout = 10 mA, and Rs = 5 Ω, the transfer term is 1/(100,000 × 1 μF) = 10 Ω. Total modeled output resistance is 15 Ω, so the load-related drop is 0.010 × 15 = 0.15 V. Thus Vout is about 10 − 0.60 − 0.15 = 9.25 V.

The reservoir ripple estimate is ΔVpp = Iout/(fsCo) = 0.010/(100,000 × 100 μF) = 0.001 V, or 1 mV peak-to-peak. With 3.3 V drive, 0.40 V drops, 2.2 μF flying capacitance, 47 μF reservoir, 50 kHz, 20 mA, and 8 Ω, effective resistance is about 17.091 Ω. The model then gives roughly 5.458 V and 8.51 mV ripple.

Worked examples

Five-volt doubler at a 10 mA load

Inputs: Vin = 5 V, Vf = 0.30 V, Cf = 1 μF, Co = 100 μF, fs = 100 kHz, Iout = 0.010 A, Rs = 5 Ω.

Calculation: Rout = 1/(100,000 × 1 × 10⁻⁶) + 5 = 15 Ω; Vout = 10 − 0.60 − 0.010 × 15 = 9.25 V; ΔVpp = 0.010/(100,000 × 100 × 10⁻⁶) = 0.001 V.

The estimate is 9.25 V average output and 1 mV peak-to-peak reservoir ripple under the stated simplified assumptions.

Lower-frequency pump with a larger load

Inputs: Vin = 3.3 V, Vf = 0.40 V, Cf = 2.2 μF, Co = 47 μF, fs = 50 kHz, Iout = 20 mA, Rs = 8 Ω.

Calculation: Rout = 1/(50,000 × 2.2 × 10⁻⁶) + 8 = 17.0909 Ω; Vout = 6.6 − 0.8 − 0.020 × 17.0909 = 5.45818 V; ΔVpp = 0.020/(50,000 × 47 × 10⁻⁶) = 0.0085106 V.

The lower refresh rate and larger load increase both modeled droop and ripple relative to the first case, though the input and capacitances also differ.

An output waveform rises at refresh events and slopes downward between them around a mean voltage.
The ripple estimate describes the reservoir swing; load current also lowers the modeled average output.

Interpret output and ripple separately

The output estimate falls linearly with load current because current is multiplied by the modeled output resistance. Increasing Cf or refresh frequency lowers the 1/(fsCf) contribution; reducing Rs lowers only the additional-resistance contribution. Increasing Co or refresh frequency reduces the ripple estimate, but it does not remove the load-dependent output drop in the first equation.

A low ripple does not prove a stiff supply. Larger Co can reduce cycle swing while average remains below no-load doubling. Read outputs separately: effective resistance estimates average droop; ΔVpp estimates reservoir swing.

Check units and energy-transfer conditions

Capacitance must be entered in farads, not microfarads as an unscaled number. For example, 1 μF is 1 × 10⁻⁶ F. Frequency is entered in hertz, so 100 kHz means 100,000. Current is in amperes: 10 mA is 0.010 A. A unit slip can move the predicted resistance or ripple by factors of a thousand or a million.

The approximation assumes the flying capacitor is fully recharged each cycle and that the ripple is small enough for the average-current model to be useful. If the load consumes more charge than the pump transfers, the calculated output can reach zero or below; the runtime rejects a negative average output because the assumed positive-output operating state no longer applies.

Validate against the actual waveform

Measure the output at the reservoir capacitor with an oscilloscope probe and a load that matches the entered current. Confirm the drive amplitude and frequency at the pump pins, not only at the signal generator. Probe ground placement and bandwidth can affect a small ripple measurement, so keep the setup and coupling consistent when comparing cases.

The model omits nonlinear switch resistance, diode drop, capacitor ESR and tolerance, parasitic inductance, startup, and regulation. Use it for relative estimates; check the actual topology and components in datasheets or a validated circuit test before relying on the rail.

Sources and further reading

Share this article

Browse all articles · Calculator: Diode doubler loaded output and ripple calculator