Use limits rather than nominal sizes
The calculation begins with four values: the minimum and maximum permitted hole size, plus the minimum and maximum permitted shaft size. All four must describe the same mating feature and use the same unit. The calculator compares these endpoints directly; it does not infer them from an ISO fit designation or a nominal diameter.
Minimum clearance is hole minimum minus shaft maximum. Maximum clearance is hole maximum minus shaft minimum. A positive clearance means the hole is larger at that limit combination; a negative value means the shaft would be larger by the absolute amount, which is interference.
Classify the full possible fit range
If both clearance endpoints are positive, every combination in the stated size limits has clearance. If both are negative, every combination has interference. If the interval crosses zero, some permitted combinations have clearance and others have interference, so the checker labels it a transition fit. Zero itself represents line-to-line contact in this simplified size comparison.
The classification uses the two extremes, not the relative probability of different part sizes. A process centered near one end of its tolerance may produce a different mix than a process centered near the other, but this calculator has no process distribution or capability inputs and cannot estimate that mix.
Enter four sizes in one unit
The fields are numeric millimetre sizes and accept positive values within the calculator’s stated input range. Enter the drawing’s actual lower and upper limits for the hole and shaft. Keep the order clear: a hole minimum cannot exceed its maximum, and a shaft minimum cannot exceed its maximum, even if the form accepts each number individually.
Avoid rounding limits before subtraction. A few micrometres can change a marginal classification, especially when the interval crosses zero. If the drawing uses micrometres or inches, convert all four values consistently and retain enough decimal places to preserve the tolerance difference.
What clearance does and does not say
A clearance range helps screen whether two size features can assemble without dimensional overlap. It does not calculate insertion force, contact pressure, retention, lubrication film, runout, or life. A press fit’s performance depends on more than the amount of interference, including material properties, wall thickness, surface finish, and assembly method.
Likewise, a positive clearance does not guarantee free motion. Form error, alignment, coating, thermal expansion, contamination, and load can reduce functional clearance. Treat the computed range as a size-limit comparison and return to the full drawing and operating conditions before release.
When to consult the fit standard
A fit designation is selected from a tolerance system that relates a nominal size, tolerance class, and deviations. The calculator deliberately starts after that selection: it checks supplied limits. It does not choose a hole-basis or shaft-basis class, determine a preferred fit, or confirm that a standard applies to a particular industry or jurisdiction.
For production, verify the drawing revision, units, tolerance class, inspection method, and any geometric controls that affect the mating surfaces. If measurement uncertainty is similar to the calculated clearance margin, account for it in the inspection decision. The arithmetic is useful only when its limit sizes and context are correct.
Worked examples
Each example subtracts opposite limit endpoints; the sign of the resulting interval determines the simplified fit class.
Clearance across both limits
Inputs: Hole = 25.010–25.030 mm; shaft = 25.000–25.008 mm.
Calculation: Minimum clearance = 25.010 − 25.008 = 0.002 mm; maximum clearance = 25.030 − 25.000 = 0.030 mm. Both are positive: clearance fit.
Even the smallest hole is 0.002 mm larger than the largest shaft under these limits. The calculator classifies size clearance; it does not assess alignment or surface form.
An interval that crosses zero
Inputs: Hole = 40.000–40.020 mm; shaft = 40.010–40.030 mm.
Calculation: Minimum clearance = 40.000 − 40.030 = −0.030 mm; maximum clearance = 40.020 − 40.010 = 0.010 mm. The interval crosses zero: transition fit.
The limiting combinations range from 0.030 mm interference to 0.010 mm clearance. The calculation does not tell how often either condition will occur.