Ideal Op-Amp Differentiator: Slope, Sign, and Noise Limits

An ideal op-amp differentiator turns a changing input voltage into an output proportional to its slope. With a 22 kΩ feedback resistor, a 10 nF input capacitor, and an input rising at 0.5 V/ms, the model gives −0.11 V. A falling slope of −0.2 V/ms with 47 kΩ and 4.7 nF gives +0.04418 V. The sign reverses because this is an inverting circuit; the result is a local slope estimate, not a general prediction for noisy or bandwidth-limited hardware.

Open calculator
A rising and falling input ramp are paired with the inverted output levels they produce in the ideal differentiator.

Share this article

An input capacitor drives the inverting node of an op amp and a feedback resistor returns output to that node.
The input capacitor turns voltage slope into current, and the feedback resistor converts that current into an inverted output.

What the circuit measures

The ideal inverting differentiator places a capacitor in the input path and a resistor in the feedback path. The noninverting input is held at a reference, often ground. When the input changes, current through the capacitor is proportional to the rate of change; feedback through the resistor produces the output voltage needed to balance that current. A constant input therefore produces zero ideal output after transients, while a ramp with constant slope produces a constant output.

This makes the circuit useful as a conceptual model for edge detection, rate sensing, and the response of a capacitive-input amplifier. It does not measure the input level itself. Two waveforms that pass through the same voltage can produce different outputs if their slopes differ, and a waveform that is momentarily flat produces a zero ideal derivative even when its voltage is not zero.

Set up the differentiator relation

For feedback resistance Rf and input capacitance C, the ideal transfer is Vout = −Rf C × dVin/dt. The minus sign comes from the inverting topology. A rising input slope produces a negative output; a falling slope produces a positive output. Reversing the input slope reverses the result without changing its magnitude when the component values stay fixed.

The calculator labels the resistance in kΩ, capacitance in nF, and slope in V/ms. Convert those units consistently: Rf in ohms is the entered value times 1,000, C in farads is the entered value times 10⁻⁹, and V/ms is multiplied by 1,000 to obtain V/s. The combined conversion gives Vout in volts. Enter a slope with its sign; entering only its magnitude discards the direction needed to determine output polarity.

Worked examples

A rising ramp produces a negative output

Inputs: Rf = 22 kΩ, C = 10 nF, dVin/dt = +0.5 V/ms.

Calculation: Vout = −(22,000 Ω)(10 × 10⁻⁹ F)(500 V/s) = −0.11 V.

The ideal output is negative while the input rises. The predicted amplitude still has to fit the amplifier’s supply and output-swing limits.

A falling ramp reverses the output sign

Inputs: Rf = 47 kΩ, C = 4.7 nF, dVin/dt = −0.2 V/ms.

Calculation: Vout = −(47,000 Ω)(4.7 × 10⁻⁹ F)(−200 V/s) = +0.04418 V.

The component product is unchanged in form, but the negative input slope makes the inverting output positive.

A rising input ramp aligns with a negative output level, while a falling input ramp aligns with a positive output level.
The output sign is opposite the signed input slope in the ideal inverting model.

Read the output as a local response

A differentiator responds to change over time, so the slope must describe the interval of interest. For a curved waveform, the derivative varies; one entered value represents a local segment or short-interval average. Do not treat a full-record endpoint average as an exact instantaneous slope unless the waveform is linear over that interval.

For fixed components, doubling the input slope doubles ideal output magnitude; doubling Rf or C does the same. A larger response can consume output swing, so proportionality alone does not establish a useful or feasible circuit setting.

Check two signed slope examples

The examples use the field units exactly as shown. Compute the product of resistance, capacitance, and signed slope, then apply the negative sign once. Keep the result in volts and compare it with the expected output range of any real amplifier before using it as a circuit target.

Why an ideal differentiator is noise-sensitive

Differentiation weights faster changes more strongly. Its ideal frequency response rises with frequency, so broadband noise and switching edges can dominate the output. This model includes no cutoff, component parasitics, amplifier noise, slew-rate limit, or phase-margin analysis; an ideal DC result cannot establish whether hardware is stable or quiet.

Practical differentiators add resistors or capacitors to limit response, which changes the transfer function and useful band. Analyze those parts from the actual schematic rather than applying the ideal equation as if it included filtering. The ideal op-amp integrator calculator models complementary accumulation but also omits real bandwidth and drift.

Verify a slope measurement before choosing parts

For a bench check, record two input voltages and elapsed time, then calculate signed ΔV/Δt in V/ms. Use measured component values and compare the prediction with the output trace over the same interval. Confirm polarity first; a rising input should produce a negative output in this topology.

A mismatch can come from a reversed sign, seconds entered as milliseconds, finite bandwidth, clipping, or added filtering. For a sharp edge, define the measurement interval instead of assigning an infinite slope. Use the ideal differentiator calculator and record that interval.