Abrupt PN Junction Depletion Width: Bias, Doping, and Capacitance

For an abrupt silicon junction with N_A=10²² m⁻³, N_D=10²¹ m⁻³, T=300 K, and 5 V reverse bias, the estimated depletion width is about 2.84 µm, mostly on the lightly doped n side. This guide explains the SI inputs, built-in voltage, charge balance, and the limits of the model.

Open calculator
A p-n junction shows the depletion region extending farther into the more lightly doped side.

Share this article

Uniform p and n doping meet at a junction, with a narrow p-side and wider n-side depletion region under reverse bias.
Charge neutrality makes the depletion widths unequal when doping is asymmetric.

What depletion width represents

When p-type and n-type material meet, mobile carriers diffuse and leave ionized dopants near the junction. This depleted region supports an electric field and potential barrier. Reverse bias raises the barrier and generally widens the region.

The calculator returns total width W, the n-side portion, and depletion capacitance per unit area. These are electrostatic estimates, not the thickness of a fabricated layer or a direct measurement of a packaged diode.

Enter concentrations and material properties in SI units

Enter acceptor density N_A, donor density N_D, and intrinsic density n_i in m⁻³; they are concentrations, not sheet densities. The model requires N_A and N_D to exceed n_i. Temperature is in kelvins, ε_r is dimensionless, and reverse bias V_R is in volts and nonnegative.

Doping data are often reported in cm⁻³. Convert before entry: 1 cm⁻³ equals 10⁶ m⁻³, so 10¹⁶ cm⁻³ becomes 10²² m⁻³. Entering 10¹⁶ directly into a field expecting m⁻³ changes the inferred width substantially. The intrinsic density depends on material and temperature; use values consistent with the semiconductor assumptions of the problem.

Calculate built-in voltage and depletion width

The built-in potential is V_BI=(k_BT/q) ln(N_A N_D/n_i²), where k_B is Boltzmann’s constant and q is elementary charge. The depletion-width relation is W=√[(2ε/q)(V_BI+V_R)(1/N_A+1/N_D)], with ε=ε₀ε_r. Adding reverse bias increases the potential drop supported across the depleted region, so the model predicts a wider region.

Charge neutrality divides the total width asymmetrically: N_A x_p=N_D x_n and W=x_p+x_n. Therefore x_n=W N_A/(N_A+N_D), while x_p=W N_D/(N_A+N_D). If the p side is more heavily doped, its depletion segment is smaller; most of the field-supporting width extends into the lightly doped side.

The small-signal depletion capacitance per area is C_j/A=ε/W. A wider depletion region corresponds to a lower capacitance density in this parallel-plate approximation. This output is per square metre; obtaining a total capacitance requires junction area and assumes the one-dimensional uniform junction model remains appropriate.

Worked examples

A reverse-biased asymmetric junction

Inputs: N_A=1×10²² m⁻³, N_D=1×10²¹ m⁻³, n_i=1×10¹⁶ m⁻³, T=300 K, ε_r=11.7, V_R=5 V.

Calculation: V_BI=(kT/q)ln[(10²²/10¹⁶)(10²¹/10¹⁶)]=0.65479 V. With ε=11.7ε₀, W=2.83617 µm; x_p=0.25783 µm and x_n=2.57833 µm. C_j/A=ε/W=3.65261×10⁻⁵ F/m².

The depletion region is about 2.84 µm wide and extends ten times farther into the lighter-doped n side than into the p side.

Increasing both doping densities

Inputs: N_A=5×10²² m⁻³, N_D=2×10²² m⁻³, n_i=1×10¹⁶ m⁻³, T=300 K, ε_r=11.7, V_R=10 V.

Calculation: The built-in potential is 0.77384 V. Applying the abrupt-junction relation gives W=0.98756 µm, x_p=0.28216 µm, x_n=0.70540 µm, and C_j/A=1.04899×10⁻⁴ F/m².

Higher dopant densities narrow the total depletion region at this bias; the more heavily doped p side still has the shorter depletion segment.

The abrupt-junction equation combines built-in potential, reverse bias, permittivity, and both dopant densities to estimate total width.
Reverse bias widens the depletion region; capacitance density varies inversely with width.

Check charge balance and units

A useful manual check is to compare the dopant charge magnitudes on each side: N_A x_p should equal N_D x_n. Their values will not be equal in length, but their products should match. Also verify x_p+x_n=W and confirm that all three lengths use metres before converting to micrometres for presentation.

The width is in metres, so multiply by 10⁶ for micrometres. Capacitance density is in F/m². It is not a total capacitance; multiplying by junction area is appropriate only when the one-dimensional uniform-junction approximation is suitable.

When the abrupt-junction model can mislead

The depletion approximation treats mobile carriers as absent in the space-charge region and assumes uniform, fully ionized dopants. It is most useful for a one-dimensional abrupt junction. A graded profile, interface charge, or complex device geometry may need another model.

The built-in-voltage expression also assumes nondegenerate carriers and a compatible equilibrium model. At very high doping or low temperature, degeneracy or incomplete ionization can matter. Positive inputs pass arithmetic checks but do not prove the material assumptions are valid.

The model does not calculate breakdown, leakage current, diffusion capacitance, or switching speed. Do not read depletion width as a safe-voltage rating; use device-specific limits for those questions.

A practical way to use the estimate

Record the material source and units with the result. Equal numbers are not comparable if one concentration was entered in cm⁻³ and another in m⁻³. Treat the output as a first-order check against a device model or measurement.

Compare the estimate only with a model using the same temperature, doping profile, and bias convention. If those assumptions differ, a mismatch may reflect the model rather than arithmetic; retain the inputs and units so the comparison can be reproduced.

Sources and further reading

Share this article

Browse all articles · Calculator: Abrupt PN junction depletion width calculator