What Cp measures
The index is Cp = (USL − LSL) / (6σ). USL is the upper specification limit, LSL is the lower limit, and σ is the process standard deviation. The numerator is the allowed width; the denominator is a six-sigma spread estimate. Both limits and σ must use the same measurement unit, such as millimetres or grams, so the ratio has no unit.
Cp describes spread against tolerance under a centered-process interpretation. It does not include the observed mean. Two processes can therefore have the same Cp even when one is centered and the other sits close to a specification edge. Use Cp as one part of a capability review, then inspect a mean-sensitive index and process evidence before making a quality decision.
Enter compatible limits and variation
Enter the upper limit, lower limit, and a positive standard deviation. The calculator starts with USL 110, LSL 90, and σ 3 as example values; they are not universal defaults or recommended tolerances. Choose a standard deviation that matches the method and period you are evaluating, and document how it was estimated. It checks that USL exceeds LSL and that σ is positive.
Keep units consistent. If a tolerance is 0.20 mm wide and the standard deviation is recorded in micrometres, convert one scale first: 0.20 mm equals 200 μm. Entering 0.20 and 10 without conversion would produce a numerically valid ratio with no sensible physical interpretation. Use the Cp calculator after confirming the specification boundaries are the ones that apply to the product and customer.
Worked examples
The calculations below use two different measurement scales. In each case the ratio is dimensionless; changing all inputs to another common unit would leave Cp unchanged.
A 20 mm specification span
Inputs: USL = 110 mm; LSL = 90 mm; σ = 3 mm
Calculation: Cp = (110 − 90) / (6 × 3) = 20 / 18 = 1.111111…
Cp displays as 1.1111. The tolerance width is 1.111 times the entered six-sigma spread.
A wider range with lower variation
Inputs: USL = 50 cm; LSL = 40 cm; σ = 1.25 cm
Calculation: Cp = (50 − 40) / (6 × 1.25) = 10 / 7.5 = 1.333333…
Cp displays as 1.3333. The result compares spread with tolerance only; it does not show the process mean.
Interpret Cp alongside the process mean
In the first example, Cp = 1.1111 means the tolerance width is about 1.111 times the modeled six-sigma spread. It is not a percent conforming, a defect probability, or evidence that the actual process has the assumed distribution. A value below one means the entered six-sigma width exceeds the specification width; a value above one means the entered spread estimate is narrower.
Cp alone cannot answer how close the process is to either limit. A centered mean may leave equal room on both sides, while a shifted mean can make one side critical without changing the spread. Compare Cp with Cpk when a suitable within-process standard deviation and mean are available, and review a control chart or other stability evidence. Do not treat a single index threshold as an automatic release rule.
Assumptions and boundaries
A capability interpretation depends on the data and process model behind σ. NIST describes capability indices in the context of a stable process and distribution assumptions; this calculator receives one summary value and cannot test stability, normality, sampling design, or independence. If a process is drifting, mixing shifts, or has a strongly non-normal output, one Cp value can conceal important behavior.
The calculator also does not estimate σ from raw measurements, calculate confidence intervals, or translate Cp into an expected defect rate. Keep the data window, subgroup method, units, limits, and calculation date with the result. If the standard deviation comes from a short or selected sample, explain that limitation. Use the index to frame a question for analysis, not as a substitute for measurement-system review or process monitoring.