Shaft Torque from Power and Rotational Speed

A shaft transmitting 7.5 kW at 1,500 rpm carries about 47.74648293 N·m of torque in the ideal steady-power relation. Torque is not determined by power alone: the same power at a lower speed requires more torque. This guide shows how to enter matched shaft values, convert rpm to angular velocity, and keep the result distinct from motor nameplate or downstream output torque.

Open calculator
Mechanical power and rotational speed enter a rotating shaft relation that yields torque magnitude.

Share this article

Mechanical power and rotational speed enter a rotating shaft relation that yields torque magnitude.
Power and speed must refer to the same shaft and operating point.

Interpret the result at the same shaft

Mechanical power is the rate of energy transfer. For steady rotation, shaft power equals torque multiplied by angular velocity, P = Tω. The calculator solves this relation for torque magnitude from power in kilowatts and speed in revolutions per minute. It does not infer direction, and its displayed torque is the ideal value at the shaft where both inputs apply.

Use values from the same operating point and shaft. Motor electrical input power is not the same as mechanical output power because losses intervene. A gearbox or belt drive can change speed and torque while transferring less power than it receives. If the power is specified after a drive and speed before it, the pair does not describe one shaft and gives a misleading result.

Map the two inputs to the specification

Enter mechanical power in kW and rotational speed in rpm. Source validation accepts finite nonnegative power and requires speed to be strictly greater than zero; zero speed would make the inverse calculation undefined. A zero power input returns zero torque. The tool returns a nonnegative magnitude, so it is appropriate for sizing arithmetic where direction is handled separately.

Read the power definition carefully: rated, shaft, absorbed, and electrical power can refer to different points or conditions. Confirm whether speed is synchronous, nominal, or measured under load. If power and speed vary during a cycle, one pair represents one operating condition, not a peak or time history. For a changing load, calculate representative cases rather than treating an average as the maximum.

Convert rpm and solve for torque

First convert rotational speed n to angular velocity: ω = 2πn/60 radians per second. Then T = P/ω. Because power is entered in kW, use watts in the SI equation: T in N·m = PkW × 1,000 ÷ (2πn/60), or T = 60,000PkW/(2πn). The equivalent shortcut is approximately 9,549.3 × PkW/n, with units retained.

For 7.5 kW at 1,500 rpm, ω = 1,500×2π/60 = 157.0796 rad/s. Torque = 7,500/157.0796 = 47.7464829 N·m. This inverse relationship means doubling rpm at unchanged power halves torque. Leaving kW unconverted to watts would produce an answer one thousand times too small.

Compare another operating point

At 5.5 kW and 960 rpm, ω = 100.5310 rad/s and T = 5,500/100.5310 = 54.7095117 N·m. Although this case transmits less power than the first, its lower rotational speed results in greater torque. That comparison illustrates why a power rating alone cannot specify shaft loading.

Hold speed at 960 rpm and raise power from 5.5 to 8 kW: torque rises in direct proportion, from about 54.70951 to 79.57747 N·m. Hold power at 5.5 kW but halve speed to 480 rpm: torque doubles to about 109.41902 N·m. These checks are useful for seeing whether a drive ratio or operating point creates a high-torque region.

Limits and a practical verification

The equation describes steady rotational power at a shaft. It does not include acceleration torque, friction, starting transients, torque ripple, transmission efficiency, or peak loads. If the requested quantity is torque at a gearbox output, first determine output power and output speed, or apply a justified efficiency model. Do not add a loss percentage without identifying where the loss is measured.

To verify a result, convert rpm to rad/s and multiply the displayed torque by angular speed; the product should return entered mechanical power in watts. Record whether the values are rated or measured and whether they refer to the same shaft. If the drive accelerates, use rotational dynamics and inertia in addition to power balance. This calculator is a steady-state relationship, not a drive-selection or safety assessment.

Shaft torque equals entered kilowatts times 60,000 divided by two pi times revolutions per minute.
Convert kW to W and rpm to radians per second before dividing.

Worked examples

Motor shaft at 1,500 rpm

Inputs: Mechanical shaft power = 7.5 kW; shaft speed = 1,500 rpm.

Calculation: ω = 1,500 × 2π/60 = 157.0796 rad/s; T = 7,500/157.0796 = 47.7464829 N·m.

Shaft torque magnitude = 47.74648293 N·m.

Lower-speed operating point

Inputs: Mechanical shaft power = 5.5 kW; shaft speed = 960 rpm.

Calculation: ω = 960 × 2π/60 = 100.53096 rad/s; T = 5,500/100.53096 = 54.7095117 N·m.

Shaft torque magnitude = 54.70951169 N·m.