Choose inputs that describe the same array
Enter the DC array rating in kW, not an individual module’s wattage unless that is the entire array. For a 5 kW system made from twenty-five 200 W modules, the field is 5 kW. Peak sun hours are an irradiation equivalent, not the number of clock hours between sunrise and sunset: 4.5 peak sun hours represents 4.5 kWh/m² of daily solar irradiation under the common 1 kW/m² reference convention.
The performance ratio is entered as a fraction, so 0.80 means 80 percent. It summarizes the share of the idealized energy estimate retained after system effects represented by the chosen value. The tool accepts finite, nonnegative array power and sun hours and limits this ratio to 0 through 1. It does not infer the ratio from a module label, roof pitch, or inverter nameplate.
Follow the energy calculation
The calculator multiplies rated power by peak sun hours and by the performance ratio: daily energy = kW × h/day × fraction. Since a kilowatt is a kilowatt-hour per hour, multiplying by hours leaves kilowatt-hours. At 5 kW, 4.5 peak sun hours, and a ratio of 0.80, the estimate is 18 kWh/day. The equation is linear: holding the other inputs fixed, a 10 percent change in any one factor changes the result by 10 percent.
This compact model deliberately keeps the solar resource and the system-performance assumption visible as separate terms. A location’s monthly irradiation, array orientation, temperature, shading, soiling, inverter clipping, outages, and wiring losses can all affect production. A detailed model such as NREL PVWatts uses weather and system choices to estimate output; this three-input arithmetic is useful for a quick scenario, a hand check, or comparing assumptions before that deeper analysis.
Use the estimate for a planning question
Start with a clearly defined day or representative daily irradiation value. A long-term monthly average can be divided by the number of days in that month for an average-day estimate, but that result will smooth over cloudy sequences and seasonal variation. For a day-specific forecast, use a forecast or production model rather than treating a climatological average as a schedule.
A household might compare 18 kWh/day of estimated PV generation with its own average daily use. That comparison is an energy balance only. It does not show when generation occurs, whether appliances run during those hours, how much a battery can shift, or how much energy is imported or exported. A system can produce enough energy over a day and still draw from the grid during the evening peak.
Read the result at its displayed precision
The calculator displays kWh/day to four decimal places and shows the input values alongside the equation. Extra digits are a formatting choice, not a claim that weather, module rating, or the selected ratio is known to that precision. Keep a practical estimate rounded to the precision of the underlying resource data and state whether it is an average day, a design day, or a recent measured day.
For a second independent scenario, a 7.2 kW array, 3.8 peak sun hours, and a 0.78 ratio give 21.3408 kWh/day before practical rounding. The worked cards retain the full arithmetic so the reader can see where the value came from. Neither scenario accounts for panel mismatch or inverter power limits unless those effects are represented by the chosen performance ratio.
Worked examples
A representative spring day
Inputs: Array 5 kW; peak sun hours 4.5 h/day; performance ratio 0.80.
Calculation: 5 kW × 4.5 h/day × 0.80 = 18 kWh/day.
Estimated daily production is 18 kWh. This is an energy estimate, not a promise of a fixed hourly output.
A larger array under a different resource
Inputs: Array 7.2 kW; peak sun hours 3.8 h/day; performance ratio 0.78.
Calculation: 7.2 × 3.8 × 0.78 = 21.3408 kWh/day.
The scenario estimates about 21.34 kWh/day. The larger nameplate rating outweighs the lower irradiation assumption in this comparison.
Know what a daily kWh figure cannot decide
The output is energy, not power at a particular instant. It does not size a battery, determine a solar charge controller, predict a monthly utility bill, or confirm that a roof is suitable. Those questions need additional information such as load timing, battery usable energy, tariff rules, electrical limits, roof geometry, and local weather data.
Treat the performance ratio as a stated modeling assumption and revisit it when better evidence is available. Compare like with like: use the same AC or DC boundary, irradiation period, and capacity convention when checking a measured system against an estimate. If the actual meter differs, investigate the measurement interval and weather before changing the ratio to force a desired answer.