Enter daily inputs before thinking monthly
The fields are array rated power in kW, peak sun hours per day, and system performance ratio as a fraction from zero to one. A 6 kW array is entered as 6, while a 6,000 W nameplate must first be converted to 6 kW. Peak sun hours describe daily irradiation on an equivalent basis; they are not the full daylight duration and should match the location and period you intend to approximate.
Use a performance ratio such as 0.75 to represent a 75 percent retained share of the idealized resource-and-rating calculation. This is a modeling input, not a measured efficiency that the calculator discovers. The runtime rejects negative power or sun hours and rejects ratios outside 0–1. Keep the three values consistent: do not mix a winter resource estimate with a summer-only ratio unless that contrast is intentional.
Why this calculator uses thirty days
The equation is monthly energy = 30 × array kW × peak sun hours per day × performance ratio. Units reduce to kWh because the daily estimate is multiplied by thirty days. The fixed multiplier makes monthly scenarios comparable without asking for a start date or month length. With 5 kW, 4.5 hours per day, and a 0.80 ratio, the arithmetic is 30 × 5 × 4.5 × 0.80 = 540 kWh/month.
The 30-day convention is not the same as multiplying a daily figure by the number of days in February, April, or a 31-day month. Nor does it model daily variation. When a bill covers an exact interval, use measured meter data or sum daily model output for that period. The National Renewable Energy Laboratory’s PVWatts model can estimate production with location and weather data when a fixed-day product is too coarse.
Compare scenarios without hiding the assumptions
A useful comparison changes one assumption at a time. If the array rating is fixed, compare a conservative and a typical peak-sun-hours value while holding the performance ratio constant. Then show a separate sensitivity for losses. This makes it clear whether an estimated change comes from the solar resource, the system factor, or added DC capacity rather than bundling every input into one opaque monthly number.
For example, 6.4 kW, 3.2 peak sun hours, and a 0.75 ratio yield 460.8 kWh for the calculator’s 30-day period. The implied daily average is 15.36 kWh. That secondary average is useful for orientation but still hides day-to-day weather and daylight timing. It should not be treated as a guaranteed minimum generation level for every day in the month.
Interpret the rounded monthly output
The display rounds to four decimal places in kWh/month. Precision in the display does not make the input assumptions exact. If peak-sun data are an approximate monthly average or the performance ratio is a planning value, report a sensible rounded total and retain the assumptions next to it. Avoid presenting decimal places as a forecast confidence interval.
A kWh total also differs from an electricity bill. Billing can include fixed charges, demand charges, export credits, taxes, and time-varying rates. Self-consumption depends on when the PV system produces relative to loads. A 540 kWh monthly estimate can be a useful energy-planning input, but by itself it cannot say how much will be purchased from or exported to the grid.
Worked examples
A 5 kW array using the default-style assumptions
Inputs: Array 5 kW; peak sun hours 4.5 h/day; performance ratio 0.80.
Calculation: 30 × 5 × 4.5 × 0.80 = 540 kWh/month.
The 30-day estimate is 540 kWh. A named billing month can have a different number of days and weather.
A lower-resource scenario for a larger array
Inputs: Array 6.4 kW; peak sun hours 3.2 h/day; performance ratio 0.75.
Calculation: 30 × 6.4 × 3.2 × 0.75 = 460.8 kWh/month.
The estimated daily average is 460.8 ÷ 30 = 15.36 kWh/day; the monthly output is still a 30-day convention.
When a 30-day estimate is not enough
Use a weather-based simulation for a location-specific month, and use an interval meter or inverter record for observed production. Those approaches can include the actual calendar, temperature and weather patterns, orientation, shade, inverter clipping, and downtime more explicitly than this compact formula. Check that model output and meter output refer to the same AC or DC boundary before comparing them.
This calculator does not select equipment, size storage, or assess structural and electrical design. A monthly sum can mask several low-production days that matter to backup planning. For a design decision, pair the energy estimate with time-series data, load profiles, tariff details, and equipment limits. The monthly figure is a transparent arithmetic scenario, not a substitute for those inputs.