Solar Panel Degradation: Project Output Over a Service Life

Solar panel degradation changes how much energy a system may produce in later years. This calculator projects a selected year and cumulative energy from first-year production, a constant annual decline, and a service-life duration. It is a scenario model, not a site-specific yield forecast. Use the solar PV degradation and lifetime energy calculator to check a stated assumption.

Open calculator
A solar array with an output trend line showing gradual annual decline across a multi-year timeline.

Share this article

A constant fractional degradation rate produces a gently declining annual energy curve from the first-year baseline.
Each year applies the same fractional decline.

Separate degradation from weather variation

Annual PV output can vary with solar resource, temperature, availability, shading, snow, soiling, and equipment condition. Degradation is a longer-term change in system capability, and field estimates depend on the modules, measurement method, and observation period. A single annual percentage compresses that complexity into one scenario input.

The calculator assumes the same fractional reduction is applied each year after the first-year baseline. It does not infer a degradation rate from measurements or adjust for weather. Enter the expected or measured AC energy for year one, not a module DC nameplate value unless the basis of the article or scenario is explicitly DC.

Enter a first-year baseline and annual rate

Use first-year production in kWh, an annual degradation percentage from 0 to 100, and an integer operating period from 1 to 100 years. Year one is the entered baseline. Therefore a 25-year scenario applies 24 annual reductions to the selected-year result for year 25, while cumulative energy sums all 25 annual values starting with the baseline.

The rate is a fractional annual decrease, not a one-time lifetime loss. For example, 0.5% becomes 0.005 in the repeated multiplier. At 0%, the selected-year output stays equal to year one and cumulative output is simply baseline times years. At 100%, year one is unchanged and later modeled years fall to zero.

Project year n and sum the lifetime

For a nonzero rate r, energy in year n equals first-year energy multiplied by (1 − r) to the power n − 1. The cumulative value through N years is the geometric sum: first-year energy multiplied by [1 − (1 − r)^N] divided by r. The zero-rate case uses first-year energy multiplied by N to avoid division by zero.

These are separate outputs: one describes a selected year and one describes total modeled energy over the period. The calculator also reports the selected-year percentage change from the first year. It rounds the energy outputs to at most two decimals and the percentage change to at most two, which is suitable for a scenario display but not evidence of meter accuracy.

Choose an assumption that fits the evidence

Use an operating rate supported by a system warranty, project analysis, fleet study, or measured trend where available. Do not treat a published fleet average as a guarantee for a particular site or module. NREL field work reports different outcomes across technologies, measurement periods, and individual modules, which is why a scenario input should be clearly identified as an assumption.

For a measured system, normalize production for weather or compare it with a consistent modeled expectation before attributing the change to degradation. A short period can be dominated by weather, downtime, or meter changes. Replacing an inverter or module, adding shade, washing panels, or correcting a fault can change output for reasons this constant-rate model cannot represent.

Use two worked cases and state the limitations

The examples contrast a modest positive rate with a zero-rate baseline. They show how a small annual decrease compounds over time and why cumulative energy is not the year-n value multiplied by the number of years. The inputs are illustrative; a project forecast should use documented assumptions and include any availability or replacement scenario separately.

No system runs with perfectly steady generation, and actual production may decline irregularly or recover after maintenance. The model excludes downtime, replacement, degradation-rate changes, shading changes, soiling variation, weather trends, curtailment, and inverter losses beyond the first-year basis. Use it to compare scenarios, not to promise output, savings, or equipment life.

Worked examples

25-year case at 0.5% per year

Inputs: First-year AC production 7,800 kWh; annual degradation 0.5%; operating years 25.

Calculation: Year 25 = 7,800 × (1 − 0.005)^24 = 6,915.8974 kWh; cumulative = 7,800 × [1 − (1 − 0.005)^25] ÷ 0.005 = 183,736.4210 kWh.

The scenario produces about 6,915.90 kWh in year 25 and 183,736.42 kWh in total across 25 modeled years.

15-year case with no modeled decline

Inputs: First-year AC production 6,400 kWh; annual degradation 0%; operating years 15.

Calculation: Year 15 = 6,400 × (1 − 0)^14 = 6,400 kWh; cumulative = 6,400 × 15 = 96,000 kWh.

With a zero-rate assumption, every modeled year remains at 6,400 kWh and the 15-year total is 96,000 kWh.

Cumulative PV energy is the sum of annual output values that begin at the baseline and decline over time.
Cumulative yield sums every modeled year.