CalcWorldHub
Free online calculator · no signup

Band limited periodogram power calculator

Measure mean-square signal content inside a selected frequency band using a rectangular-window periodogram.

4,000 tools
Band limited periodogram power calculator — Uniform samples (signal units), Sampling frequency (Hz), Lower band edge (Hz) and calculation method
Band limited periodogram power calculator: inputs and calculation method.

How to use this calculator

Measure mean-square signal content inside a selected frequency band using a rectangular-window periodogram.

  1. Enter Uniform samples (signal units), Sampling frequency (Hz), Lower band edge (Hz), Upper band edge (Hz). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Band limited periodogram power explained

Power in selected bins0.5signal units²
Power in selected bins: 0.5 signal units² in the worked scenario.

How the calculation works

Pₖ=cₖ|Σxₙe^(−i2πkn/N)|²/(fs N); band mean-square=Σband Pₖ(fs/N). c is two for interior one-sided bins and one for DC/Nyquist.

Do not remove the mean unless you intend to exclude DC. Band edges select whole DFT bins inclusively; they do not fractionally split edge bins.

Set up the calculation

x — Uniform samples (signal units)
Chronological real samples; use a comma-separated list in the same signal units. Use comma-separated values in the stated order.
fs — Sampling frequency (Hz)
Uniform samples per second; must be positive.
lo — Lower band edge (Hz)
Include DFT bins at or above this frequency.
hi — Upper band edge (Hz)
Include bins at or below this frequency.

Limits of this model

Uniform real samples, rectangular window, no detrending and at most 256 samples; leakage can move energy across the selected edges.

Check this example

Uniform samples (signal units) = [0, 1, 0, -1, 0, 1, 0, -1]; Sampling frequency (Hz) = 8; Lower band edge (Hz) = 1; Upper band edge (Hz) = 3.

  • Power in selected bins: 0.5 signal units²
  • Band RMS: 0.707107 signal units
  • Bin spacing: 1 Hz

The eight-point sequence contains a two-hertz sine sampled at eight hertz; the one-to-three-hertz band captures its mean-square content.

Reading the outputs

Band power is a signal mean square, not watts without impedance information; RMS is its square root.

Frequently asked questions

Why does DC use a different factor?

DC has no separate negative-frequency partner to fold into the one-sided spectrum.

Are edge bins included?

Yes, when their centers lie exactly on either entered edge.

Does more zero padding add information?

No; this tool uses the actual record length without padding.

How do I use the Band limited periodogram power calculator?

Enter Uniform samples (signal units), Sampling frequency (Hz), Lower band edge (Hz), Upper band edge (Hz). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Band limited periodogram power?

Uniform samples (signal units) = [0, 1, 0, -1, 0, 1, 0, -1]; Sampling frequency (Hz) = 8; Lower band edge (Hz) = 1; Upper band edge (Hz) = 3. Power in selected bins: 0.5 signal units² Band RMS: 0.707107 signal units Bin spacing: 1 Hz The eight-point sequence contains a two-hertz sine sampled at eight hertz; the one-to-three-hertz band captures its mean-square content.