How to use this calculator
Check whether a constant-power converter demand has a feasible high-voltage battery operating point.
- Enter Open-circuit battery voltage (V), Total internal resistance (ohm), Requested terminal load power (W). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Battery constant-power load-line feasibility explained
Use Open-circuit battery voltage (V) with Total internal resistance (ohm) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
A numerical walkthrough
Open-circuit battery voltage (V) = 12.6; Total internal resistance (ohm) = 0.08; Requested terminal load power (W) = 150.
- Loaded terminal voltage: 11.562129 V
- Stable-branch current: 12.973389 A
- Internal resistive heating: 13.464707 W
A 12.6 V source with 0.08 ohm total resistance supplying 150 W develops appreciable voltage sag and internal loss before runtime is considered.
The model behind the numbers
P=I(V_OC−IR); I_LOW=2P/[V_OC+√(V_OC²−4RP)]; P_MAX=V_OC²/(4R).
Select the lower-current, higher-voltage root. The other mathematical root lies on the low-voltage branch and is not the normal regulated operating point.
What to enter
Voc— Open-circuit battery voltage (V)- Thevenin source voltage at the selected state of charge.
R— Total internal resistance (ohm)- Cell, contact and cable resistance in the load path.
P— Requested terminal load power (W)- Constant power demanded at battery terminals.
Interpreting the result
Static Thevenin model at one state of charge. No voltage cutoff, electrochemical dynamics, thermal change or converter instability.
Reading the outputs
Terminal voltage is after internal resistance; load power is not equal to the battery chemical power VOC times current.
Frequently asked questions
Why can a converter draw more current as voltage falls?
It increases current to maintain its demanded power, which can aggravate battery sag.
What happens when the discriminant is negative?
No DC operating point exists in this Thevenin model for that demanded power.
Does the maximum-power point define a safe battery limit?
No. Real current, voltage, thermal and cell protection limits usually constrain operation earlier.
How do I use the Battery constant-power load-line feasibility calculator?
Enter Open-circuit battery voltage (V), Total internal resistance (ohm), Requested terminal load power (W). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Battery constant-power load-line feasibility?
Open-circuit battery voltage (V) = 12.6; Total internal resistance (ohm) = 0.08; Requested terminal load power (W) = 150. Loaded terminal voltage: 11.562129 V Stable-branch current: 12.973389 A Internal resistive heating: 13.464707 W A 12.6 V source with 0.08 ohm total resistance supplying 150 W develops appreciable voltage sag and internal loss before runtime is considered.
Read our calculation methodology.