CalcWorldHub
Free online calculator · no signup

Boiler Blowdown Heat Recovery Calculator

Estimate heat available from boiler blowdown and the fuel-cost savings implied by a chosen recovery effectiveness.

4,000 tools
Boiler Blowdown Heat Recovery Calculator — Blowdown flow (kg/h), Blowdown enthalpy (kJ/kg), Makeup-water enthalpy (kJ/kg) and calculation method
Boiler Blowdown Heat Recovery Calculator: inputs and calculation method.

How to use this calculator

Estimate heat available from boiler blowdown and the fuel-cost savings implied by a chosen recovery effectiveness.

  1. Enter Blowdown flow (kg/h), Blowdown enthalpy (kJ/kg), Makeup-water enthalpy (kJ/kg), Assumed heat recovery effectiveness (%), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Energy calculation

How this calculation works

Boiler blowdown carries hot water out of the steam system. This estimate compares its entered enthalpy with makeup-water enthalpy, then applies a user-supplied recovery effectiveness to model a heat-recovery opportunity. It is useful for a first-pass operating-cost screen before collecting equipment and pressure data.

Inputs and units

blowdownFlowKgH — Blowdown flow (kg/h)
Measured or estimated continuous blowdown mass flow rate.
blowdownEnthalpyKJkg — Blowdown enthalpy (kJ/kg)
Specific enthalpy of the hot blowdown at the selected system state.
makeupEnthalpyKJkg — Makeup-water enthalpy (kJ/kg)
Specific enthalpy of the makeup water that would replace the discharged mass.
recoveryEffectivenessPct — Assumed heat recovery effectiveness (%)
Fraction of the entered available heat expected to be transferred usefully; this is a scenario assumption.
boilerEfficiencyPct — Boiler fuel-to-steam efficiency (%)
Useful heat divided by fuel energy input, expressed as a percentage above 0% and at most 100%.
operatingHoursYear — Operating hours per year (h)
Annual hours at the entered blowdown flow and enthalpy conditions.
fuelPricePerGJ — Fuel price ($/GJ)
Fuel price per gigajoule on the same energy basis as the boiler-efficiency estimate.

Formula

Displayed formula

Available heat (kW) = blowdown flow (kg/h) × [blowdown enthalpy − makeup-water enthalpy] (kJ/kg) ÷ 3,600. Recovered heat = available heat × recovery effectiveness. Annual recovered energy (GJ) = recovered heat (kW) × operating hours × 0.0036. Fuel avoided = annual recovered energy ÷ boiler efficiency; cost avoided = fuel avoided × fuel price.

Method

Enter mass flow and enthalpies on a consistent water/steam property basis. Recovery effectiveness is a scenario input between 0% and 100%; it is not a heat-exchanger rating supplied by the calculator. Boiler efficiency converts recovered useful heat to an estimated fuel input avoided.

Worked example

At 400 kg/h, a 720 kJ/kg blowdown enthalpy, and 105 kJ/kg makeup-water enthalpy, available heat is 400 × (720 − 105) ÷ 3,600 = 68.33 kW. At 70% recovery for 4,000 hours, recovered heat is about 688.8 GJ/year. With 82% boiler efficiency and fuel at $13/GJ, estimated avoided fuel cost is about $10,920/year.

Assumptions and limits

This is a steady-state screening estimate. It does not calculate flash-steam formation, heat-exchanger sizing, pressure losses, feedwater temperature limits, blowdown control requirements, or changes in boiler efficiency. Actual savings depend on the system design and measured operating conditions; consult a steam-system professional before sizing or purchasing equipment.

Frequently asked questions

What does the recovery percentage represent?

It is the fraction of the available heat that your scenario assumes a recovery system can transfer usefully. The calculator does not select or rate a heat exchanger.

Why compare blowdown enthalpy with makeup-water enthalpy?

The difference estimates the heat carried by each kilogram of discharged water above the replacement-water reference used in this balance.

Does this include flash steam?

No. The page uses the enthalpies you enter and does not model flashing or steam separation. A detailed flash-steam balance needs pressure-specific properties and system data.

Is the cost result a guaranteed saving?

No. It is a scenario estimate based on the entered flow, annual hours, recovery effectiveness, efficiency, and fuel price.

How do I use the Boiler Blowdown Heat Recovery Calculator?

Enter Blowdown flow (kg/h), Blowdown enthalpy (kJ/kg), Makeup-water enthalpy (kJ/kg), Assumed heat recovery effectiveness (%), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.