How to use this calculator
Compare an entered individual-pile sum against an ideal undrained group block mechanism instead of assuming capacity scales directly with pile count.
- Enter Number of piles, Individual pile nominal resistance (kN), Individual-sum efficiency, Block width (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Cohesive pile group individual versus block resistance explained
Screen the group by comparing reduced individual-pile resistance with an idealized cohesive block failure surface.
How the calculation works
Qindividual=ηnQi; Qblock=2(B+L)Dcu+BLNccu; reported screening resistance=min(Qindividual,Qblock).
The block envelope follows the outside pile group plan dimensions. The supplied Nc and efficiency are explicit assumptions, not inferred design recommendations.
Set up the calculation
n— Number of piles- Total identical piles in the group. Enter a whole number.
Qi— Individual pile nominal resistance (kN)- Single-pile resistance from a compatible method.
eta— Individual-sum efficiency- Specified reduction applied to the sum of individual pile resistances.
B— Block width (m)- Outside group block width used for the ideal block perimeter and base.
L— Block length (m)- Outside block plan length.
D— Embedded block depth (m)- Depth over which block-side undrained shear is mobilized.
cu— Representative undrained strength (kPa)- Constant undrained strength for block sides and base in this screening model.
Nc— Specified block base factor- User-specified factor multiplying cu at the block base; geometry and embedment suitability must be established separately.
Limits of this model
Simplified undrained cohesive group failure only; settlement, lateral group effects, spacing criteria and load sharing are outside the calculation. Educational model; this is not a code-compliant design check.
Check this example
Number of piles = 9; Individual pile nominal resistance (kN) = 500; Individual-sum efficiency = 0.9; Block width (m) = 3; Block length (m) = 3; Embedded block depth (m) = 12; Representative undrained strength (kPa) = 45; Specified block base factor = 9.
- Governing nominal group resistance: 4050 kN
- Reduced individual sum: 4050 kN
- Block mechanism resistance: 10125 kN
Nine piles at 500 kN each with efficiency 0.9 are compared with a 3×3 m, 12 m deep block in 45 kPa clay, using Nc=9.
The reduced individual sum is 4,050 kN and the ideal block estimate is 10,125 kN, so the screening minimum is 4,050 kN.
Reading the outputs
All three results are kN: the smaller resistance, the reduced individual sum and the ideal block resistance.
Frequently asked questions
Does a high block capacity remove settlement concerns?
No. Group settlement can govern independently of nominal resistance.
Is eta calculated from spacing?
No. It is deliberately entered because no universal efficiency formula is assumed.
Can the block dimensions equal pile spacing alone?
Use the actual outside failure-envelope convention for the chosen method, not centre spacing without edge allowance.
How do I use the Cohesive pile group individual versus block resistance calculator?
Enter Number of piles, Individual pile nominal resistance (kN), Individual-sum efficiency, Block width (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Cohesive pile group individual versus block resistance?
Number of piles = 9; Individual pile nominal resistance (kN) = 500; Individual-sum efficiency = 0.9; Block width (m) = 3; Block length (m) = 3; Embedded block depth (m) = 12; Representative undrained strength (kPa) = 45; Specified block base factor = 9. Governing nominal group resistance: 4050 kN Reduced individual sum: 4050 kN Block mechanism resistance: 10125 kN Nine piles at 500 kN each with efficiency 0.9 are compared with a 3×3 m, 12 m deep block in 45 kPa clay, using Nc=9. The reduced individual sum is 4,050 kN and the ideal block estimate is 10,125 kN, so the screening minimum is 4,050 kN.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
Reference access note: The linked FHWA Volume II PDF was not retrievable in this review. The screening equation and example were independently checked; confirm the selected block mechanism, factors and geometry convention against the governing method before design use.
Read our calculation methodology.