How to use this calculator
Inspect disturbance sensitivity and measurement-noise transmission at one loop frequency.
- Enter Open-loop real part, Open-loop imaginary part. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Complex loop sensitivity and noise transfer explained
A numerical walkthrough
Open-loop real part = -0.4; Open-loop imaginary part = -0.7.
- Sensitivity magnitude: 1.084652 ratio
- Complementary sensitivity magnitude: 0.874475 ratio
- Distance from critical point: 0.921954 ratio
The default loop point −0.4−0.7i lies near the critical point, so disturbance amplification can exceed unity.
The model behind the numbers
S=1/(1+L), T=L/(1+L), S+T=1 for complex transfers; |1+L| is distance from −1.
Enter the complex open-loop value, including controller and plant, for a negative unity-feedback loop. S+T is a complex identity; their magnitudes need not add to one.
What to enter
re— Open-loop real part- Real component of L(j omega) at one specified frequency.
im— Open-loop imaginary part- Imaginary component of L(j omega) at the same frequency.
Interpreting the result
A single point cannot establish Nyquist stability or global robustness.
Reading the outputs
S scales an output-injected disturbance; T scales the reference and the negative contribution of measurement noise to output.
Assumptions and limits
This is a scalar, linear small-signal frequency-point calculation. The sensitivity is undefined at L = −1; a finite result at one frequency does not establish closed-loop stability or characterize a multivariable system.
Frequently asked questions
Why can sensitivity exceed one?
Feedback can amplify disturbances near resonant loop frequencies.
Do the magnitudes sum to one?
No. The identity applies to complex quantities before taking magnitudes.
What occurs exactly at L=−1?
The linear closed-loop transfer denominator vanishes.
How do I use the Complex loop sensitivity and noise transfer calculator?
Enter Open-loop real part, Open-loop imaginary part. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Complex loop sensitivity and noise transfer?
Open-loop real part = -0.4; Open-loop imaginary part = -0.7. Sensitivity magnitude: 1.084652 ratio Complementary sensitivity magnitude: 0.874475 ratio Distance from critical point: 0.921954 ratio The default loop point −0.4−0.7i lies near the critical point, so disturbance amplification can exceed unity.
Read our calculation methodology.