Inspect disturbance sensitivity and measurement-noise transmission at one loop frequency.

4,000 tools
Complex loop sensitivity and noise transfer calculator — Open-loop real part, Open-loop imaginary part and calculation method
Complex loop sensitivity and noise transfer calculator: inputs and calculation method.

How to use this calculator

Inspect disturbance sensitivity and measurement-noise transmission at one loop frequency.

  1. Enter Open-loop real part, Open-loop imaginary part. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Complex loop sensitivity and noise transfer explained

Sensitivity magnitude1.0847ratio
Sensitivity magnitude: 1.084652 ratio in the worked scenario.

A numerical walkthrough

Open-loop real part = -0.4; Open-loop imaginary part = -0.7.

  • Sensitivity magnitude: 1.084652 ratio
  • Complementary sensitivity magnitude: 0.874475 ratio
  • Distance from critical point: 0.921954 ratio

The default loop point −0.4−0.7i lies near the critical point, so disturbance amplification can exceed unity.

The model behind the numbers

S=1/(1+L), T=L/(1+L), S+T=1 for complex transfers; |1+L| is distance from −1.

Enter the complex open-loop value, including controller and plant, for a negative unity-feedback loop. S+T is a complex identity; their magnitudes need not add to one.

What to enter

re — Open-loop real part
Real component of L(j omega) at one specified frequency.
im — Open-loop imaginary part
Imaginary component of L(j omega) at the same frequency.

Interpreting the result

A single point cannot establish Nyquist stability or global robustness.

Reading the outputs

S scales an output-injected disturbance; T scales the reference and the negative contribution of measurement noise to output.

Assumptions and limits

This is a scalar, linear small-signal frequency-point calculation. The sensitivity is undefined at L = −1; a finite result at one frequency does not establish closed-loop stability or characterize a multivariable system.

Frequently asked questions

Why can sensitivity exceed one?

Feedback can amplify disturbances near resonant loop frequencies.

Do the magnitudes sum to one?

No. The identity applies to complex quantities before taking magnitudes.

What occurs exactly at L=−1?

The linear closed-loop transfer denominator vanishes.

How do I use the Complex loop sensitivity and noise transfer calculator?

Enter Open-loop real part, Open-loop imaginary part. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Complex loop sensitivity and noise transfer?

Open-loop real part = -0.4; Open-loop imaginary part = -0.7. Sensitivity magnitude: 1.084652 ratio Complementary sensitivity magnitude: 0.874475 ratio Distance from critical point: 0.921954 ratio The default loop point −0.4−0.7i lies near the critical point, so disturbance amplification can exceed unity.