Cyclic lumped regenerator steady periodic heat recovery calculator

Calculate the repeating hot and cold matrix temperatures of a regenerator after startup transients have vanished.

4,000 tools
Cyclic lumped regenerator steady periodic heat recovery calculator — Regenerator matrix lumped heat capacity (J/K), Hot blow matrix-fluid conductance (W/K), Cold blow matrix-fluid conductance (W/K) and calculation method
Cyclic lumped regenerator steady periodic heat recovery calculator: inputs and calculation method.

How to use this calculator

Calculate the repeating hot and cold matrix temperatures of a regenerator after startup transients have vanished.

  1. Enter Regenerator matrix lumped heat capacity (J/K), Hot blow matrix-fluid conductance (W/K), Cold blow matrix-fluid conductance (W/K), Hot blow duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Cyclic lumped regenerator steady periodic heat recovery explained

Recovered heat per complete cycle276501.2135J
Recovered heat per complete cycle: 276501.213503 J in the worked scenario.

A numerical walkthrough

Regenerator matrix lumped heat capacity (J/K) = 10000; Hot blow matrix-fluid conductance (W/K) = 100; Cold blow matrix-fluid conductance (W/K) = 80; Hot blow duration (s) = 30; Cold blow duration (s) = 40; Prescribed hot fluid temperature (°C) = 200; Prescribed cold fluid temperature (°C) = 20.

  • Recovered heat per complete cycle: 276501.213503 J
  • Matrix temperature before hot blow: 93.31765 °C
  • Matrix temperature after hot blow: 120.967771 °C
  • Cycle averaged recovered thermal power: 3950.017336 W

A 10,000 J/K matrix alternates 30 s hot blows at 200 °C through 100 W/K and 40 s cold blows at 20 °C through 80 W/K. At periodic steady operation it cycles between 93.3176 and 120.968 °C, transferring 276.501 kJ per cycle or 3.95002 kW on average.

The model behind the numbers

a=e^(−Ght h/C), b=e^(−Gct c/C); Tlow=[Tc(1−b)+bTh(1−a)]/(1−ab); Thigh=Th+(Tlow−Th)a; Q=C(Thigh−Tlow).

Compose hot-blow and cold-blow exponential responses and enforce that each cycle returns to the same starting matrix temperature.

What to enter

C — Regenerator matrix lumped heat capacity (J/K)
Regenerator matrix lumped heat capacity (J/K). Enter the value for this state; the units shown are used without an unstated conversion.
Gh — Hot blow matrix-fluid conductance (W/K)
Hot blow matrix-fluid conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
Gc — Cold blow matrix-fluid conductance (W/K)
Cold blow matrix-fluid conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
th — Hot blow duration (s)
Hot blow duration (s). Enter the value for this state; the units shown are used without an unstated conversion.
tc — Cold blow duration (s)
Cold blow duration (s). Enter the value for this state; the units shown are used without an unstated conversion.
Th — Prescribed hot fluid temperature (°C)
Prescribed hot fluid temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
Tc — Prescribed cold fluid temperature (°C)
Prescribed cold fluid temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.

Interpreting the result

Internally uniform solid matrix, prescribed fluid temperatures, constant conductances, instantaneous switching, no leakage, axial gradients or dead time.

Reading the outputs

Recovered heat is J per hot/cold cycle, the matrix endpoint temperatures are °C, and average recovered power includes both blow durations.

Frequently asked questions

Is this the first operating cycle?

No. It is the periodic limit after repeated cycles; an initially cold matrix has a different first-cycle response.

Why include both blow durations in average power?

Heat is recovered only by alternating storage and release; the full operating cycle takes both intervals.

Can it model a long packed bed accurately?

Only if a lumped matrix approximation is adequate. Spatial thermal fronts require a distributed regenerator model.

How do I use the Cyclic lumped regenerator steady periodic heat recovery calculator?

Enter Regenerator matrix lumped heat capacity (J/K), Hot blow matrix-fluid conductance (W/K), Cold blow matrix-fluid conductance (W/K), Hot blow duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Cyclic lumped regenerator steady periodic heat recovery?

Regenerator matrix lumped heat capacity (J/K) = 10000; Hot blow matrix-fluid conductance (W/K) = 100; Cold blow matrix-fluid conductance (W/K) = 80; Hot blow duration (s) = 30; Cold blow duration (s) = 40; Prescribed hot fluid temperature (°C) = 200; Prescribed cold fluid temperature (°C) = 20. Recovered heat per complete cycle: 276501.213503 J Matrix temperature before hot blow: 93.31765 °C Matrix temperature after hot blow: 120.967771 °C Cycle averaged recovered thermal power: 3950.017336 W A 10,000 J/K matrix alternates 30 s hot blows at 200 °C through 100 W/K and 40 s cold blows at 20 °C through 80 W/K.