Lumped solid transient heating cooling calculator

Predict the temperature of a nearly uniform solid while checking the small-Biot assumption.

4,000 tools
Lumped solid transient heating cooling calculator — Solid density (kg/m³), Solid specific heat (J/kg/K), Solid volume (m³) and calculation method
Lumped solid transient heating cooling calculator: inputs and calculation method.

How to use this calculator

Predict the temperature of a nearly uniform solid while checking the small-Biot assumption.

  1. Enter Solid density (kg/m³), Solid specific heat (J/kg/K), Solid volume (m³), Exposed convection area (m²), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Lumped solid transient heating cooling explained

Use Solid density (kg/m³) with Solid specific heat (J/kg/K) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.

Predicted uniform solid temperature71.4442°C
Predicted uniform solid temperature: 71.44423515 °C in the worked scenario.

How the calculation works

T=Ta+(Ti−Ta) exp[−hAt/(ρcpV)]

Use volume divided by exposed area as characteristic length and test Bi=hLc/k. The solid thermal capacity is rho cp V and convection conductance is hA, giving the time constant. A valid small-Biot body then approaches ambient temperature exponentially.

Set up the calculation

rho — Solid density (kg/m³)
Solid density (kg/m³).
cp — Solid specific heat (J/kg/K)
Solid specific heat (J/kg/K).
vol — Solid volume (m³)
Solid volume (m³).
area — Exposed convection area (m²)
Exposed convection area (m²).
hc — Convection coefficient (W/m²/K)
Convection coefficient (W/m²/K).
k — Solid conductivity (W/m/K)
Solid conductivity (W/m/K).
ti — Initial uniform temperature (°C)
Initial uniform temperature (°C).
ta — Constant ambient temperature (°C)
Constant ambient temperature (°C).
t — Elapsed time (s)
Elapsed time (s).

Limits of this model

Requires h(V/A)/k<0.1 in this implementation. Constant properties, ambient temperature, and convection; internal generation and radiation are excluded.

Check this example

Solid density (kg/m³) = 7800; Solid specific heat (J/kg/K) = 500; Solid volume (m³) = 0.001; Exposed convection area (m²) = 0.1; Convection coefficient (W/m²/K) = 10; Solid conductivity (W/m/K) = 45; Initial uniform temperature (°C) = 80; Constant ambient temperature (°C) = 20; Elapsed time (s) = 600.

  • Predicted uniform solid temperature: 71.44423515 °C
  • Thermal time constant: 3900 s
  • Biot number: 0.00222222

Displayed values are rounded only after calculation.

Frequently asked questions

Why is Biot number checked?

Large internal temperature gradients invalidate the uniform-temperature model.

Does it handle warming as well as cooling?

Yes, the initial-to-ambient sign determines direction.

What is characteristic length here?

Volume divided by the entered exposed area.

How do I use the Lumped solid transient heating cooling calculator?

Enter Solid density (kg/m³), Solid specific heat (J/kg/K), Solid volume (m³), Exposed convection area (m²), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Lumped solid transient heating cooling?

Solid density (kg/m³) = 7800; Solid specific heat (J/kg/K) = 500; Solid volume (m³) = 0.001; Exposed convection area (m²) = 0.1; Convection coefficient (W/m²/K) = 10; Solid conductivity (W/m/K) = 45; Initial uniform temperature (°C) = 80; Constant ambient temperature (°C) = 20; Elapsed time (s) = 600. Predicted uniform solid temperature: 71.44423515 °C Thermal time constant: 3900 s Biot number: 0.00222222 Displayed values are rounded only after calculation.