Semi infinite solid surface step conduction calculator
Estimate temperature below a semi-infinite solid surface after its temperature is suddenly changed and held constant.
How to use this calculator
Estimate temperature below a semi-infinite solid surface after its temperature is suddenly changed and held constant.
- Enter Thermal diffusivity (m²/s), Depth below surface (m), Time after surface step (s), Initial solid temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How the Semi infinite solid surface step conduction calculator works
Estimate temperature below a semi-infinite solid surface after its temperature is suddenly changed and held constant.
Inputs and units
- Thermal diffusivity (m²/s): Positive thermal diffusivity in m²/s.
- Depth below surface (m): Nonnegative perpendicular depth in metres.
- Time after surface step (s): Positive time in seconds after imposing the surface step.
- Initial solid temperature (°C): Uniform initial solid temperature; signed °C values are valid.
- Fixed surface temperature (°C): Constant imposed surface temperature in °C, using the same scale as the initial value.
Formula and method
T(x,t)=Ts+(Ti−Ts) erf[x/(2√(αt))]
Worked example
α=10⁻⁶ m²/s, depth 0.01 m, time 60 s, initial 20°C, and fixed surface 100°C give T=48.90483428°C.
Interpreting the result
At zero depth the boundary temperature is Ts; farther into the solid, the material stays closer to its initial temperature.
Assumptions and limits
Assumes one-dimensional conduction, uniform initial temperature, constant properties, no internal heat generation, and a body thick enough that the far boundary is unaffected. Time and diffusivity are positive; the surface step is prescribed, not a convective boundary.
Sources and method
- Derives the error-function temperature profile for an imposed surface temperature step. NPTEL: semi-infinite slab with constant wall temperature
Frequently asked questions
Can I use a fluid temperature as Ts?
Only if the surface itself is effectively held at that temperature. A finite convection coefficient requires a different boundary model.
When does the semi-infinite approximation fail?
When thermal penetration reaches another boundary strongly enough that it affects the temperature field.
How do I use the Semi infinite solid surface step conduction calculator?
Enter Thermal diffusivity (m²/s), Depth below surface (m), Time after surface step (s), Initial solid temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Semi infinite solid surface step conduction?
α=10⁻⁶ m²/s, depth 0.01 m, time 60 s, initial 20°C, and fixed surface 100°C give T=48.90483428°C.
What does the Semi infinite solid surface step conduction calculator calculate?
Estimate temperature below a semi-infinite solid surface after its temperature is suddenly changed and held constant.
See the calculation methodology.